Start of measurement
Adjust RB to the target xy values.
MG2RXXXX
MG2BXXXX
* XXXX indicates adjustment values between 0000 - 1023 (4 digit decimal number with zero fill).
* G is fixed.
* Default adjustment value of RGB is the parameter value of LEV2 command multiplied by 4.
Repeat until values are
properly adjusted.
Adjustment gradation setting (Standard value 1 = 50 gradation)
LEV60050
Correct G value.
MG1GXXXX
When G is changed at adjustment gradation setting (standard value 6 = 236 gradation), calculate
the ratio of the change and set the following value to XXXX: (the value set with LEV1) x 4 x (the ratio).
Start of measurement
Adjust RB to the target xy values.
MG1RXXXX
MG1BXXXX
* XXXX indicates adjustment values between 0000 - 1023 (4 digit decimal number with zero fill).
* G is fixed.
Repeat until values are
* Default adjustment value of RGB is the parameter value of LEV1 command multiplied by 4.
properly adjusted.
Save adjustment values.
MSET0003
Completion of adjustment
Turn off AC power
Reflecting adjustment values to
Adjustment values are set.
OK
Pattern display
Adjustment value is set.
OK
Adjustment value is set.
OK
Reflecting adjustment values to
Adjustment values are set.
OK
Adjustment values are saved.
OK