Sharp LC-45GD5U Service Manual page 36

Hide thumbs Also See for LC-45GD5U:
Table of Contents

Advertisement

LC-45GD5U
Repeat until
values are
properly
adjusted
Repeat until values are
properly adjusted.
Repeat until values are
properly adjusted.
1
Start of measurement
Adjust RB to the target xy values.
MG5RXXXX
MG5BXXXX
* XXXX indicates adjustment values between 0000 - 1023 (4 digit decimal number with zero fill).
* G is fixed.
* Default adjustment value of RGB is the parameter value of LEV5 command multiplied by 4.
Adjustment gradation setting (Standard value 4 = 144 gradation)
LEV40144
Correct G value.
MG4GXXXX
When G is changed at adjustment gradation setting (standard value 6 = 236 gradation), calculate
the ratio of the change and set the following value to XXXX: (the value set with LEV4) x 4 x (the ratio).
Start of measurement
Adjust RB to the target xy values.
MG4RXXXX
MG4BXXXX
* XXXX indicates adjustment values between 0000 - 1023 (4 digit decimal number with zero fill).
* G is fixed.
* Default adjustment value of RGB is the parameter value of LEV4 command multiplied by 4.
Adjustment gradation setting (Standard value 3 = 116 gradation)
LEV60116
Correct G value.
MG3GXXXX
When G is changed at adjustment gradation setting (standard value 6 = 236 gradation), calculate
the ratio of the change and set the following value to XXXX: (the value set with LEV3) x 4 x (the ratio).
Start of measurement
Adjust RB to the target xy values.
MG3RXXXX
MG3BXXXX
* XXXX indicates adjustment values between 0000 - 1023 (4 digit decimal number with zero fill).
* G is fixed.
* Default adjustment value of RGB is the parameter value of LEV3 command multiplied by 4.
Adjustment gradation setting (Standard value 2 = 66 gradation)
LEV60066
Correct G value
MG2GXXXX
When G is changed at adjustment gradation setting (standard value 6 = 236 gradation), calculate
the ratio of the change and set the following value to XXXX: (the value set with LEV2) x 4 x (the ratio).
2
Reflecting adjustment values to
Adjustment values are set.
OK
Pattern display
Adjustment value is set.
OK
Adjustment value is set.
OK
Reflecting adjustment values to
Adjustment values are set.
OK
Pattern display
Adjustment value is set.
OK
Adjustment value is set.
OK
Reflecting adjustment values to
Adjustment values are set.
OK
Pattern display
Adjustment value is set.
OK
Adjustment value is set.
OK
36
1
images
images
images
2

Advertisement

Chapters

Table of Contents
loading

Table of Contents