ments, changing data, saving data
changes and exiting the Service
Mode is the same as in previous
models. These procedures are
shown in flow chart form in Fig-
ure 4-2.
Internal Test Pattern
To activate the internal Test Pat-
tern used for all service adjust-
ments, press "REWIND" when in
the Service Mode. Figure 4-3
illustrates the internal Test Pattern.
Service Adjustments
There are only 5 Service Adjust-
ments in the V26 model series.
This are seldom, if ever needed.
If the Light Engine or Chassis is
replaced these adjustments may
be needed.
The five adjustments are:
1) Horizontal Position (electrical)
2) Vertical Position (electrical)
3) Picture Rotation (mechanical)
4) Horizontal Keystone (mechani-
cal)
5) Vertical Keystone (mechanical)
Position Adjustments
1) Enter the Service Mode
"MENU-2-4-5-7"
2) Press "REWIND" ... activates the
Test Pattern
3) Select the Format function ...
"AUDIO" button
4) Select Item #1 ... HPOS
(VIDEO button)
5) Adjust data to center the picture horizontally.
6) Select Item #2 ...VPOS (VIDEO button)
7) Adjust Data to center the picture vertically.
8) Press "ENTER" to save data changes.
ON: DO NOT set VPOS data to 255 oress
CAUTION: DO NOT set VPOS data to
255 or 0 and press Enter. The picture
may freeze and blank out.
4-2