  • Page 1 Operating and Installation instructions Rangehood DA 2250, DA 2250 EXT DA 2270, DA 2270 EXT DA 2210 en - AU, NZ To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Contents Caring for the environment ......... . 3 Warning and Safety instructions .
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is at the owner's risk. requirements. Inappropriate use Miele cannot be held liable for damage can, however, lead to personal injury resulting from incorrect or improper use and damage to property.
  • Page 5: Technical Safety

    Faulty components must only be the data plate correspond to the on-site replaced by genuine Miele original electricity supply, otherwise the parts. The manufacturer can only appliance could be damaged. Consult guarantee the safety of the appliance a qualified electrician if in any doubt.
  • Page 6 These models may only be combined with a Miele external motor. This rangehood must not be installed and operated in mobile installations (e.g. on a ship).
  • Page 7 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the extractor and the heater are in operation simultaneously, an underpressure in the room of 0.04 mbar (4 pa) is the maximum permissible.
  • Page 8: Correct Use

    Warning and Safety instructions Correct use Do not use the rangehood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the rangehood. To avoid the danger of into the appliance and hindering its fire, do not flambé...
  • Page 9: Correct Installation

    Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from Miele or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11 Guide to the appliance a Control panel i Touch control for the charcoal filter b Joystick The indicator lamp for the charcoal filter This is used to operate the fan settings lights up when the charcoal filters used and the lighting. in recirculation mode needs to be c Cooktop lighting replaced.
  • Page 12: Modes Of Operation

    Modes of operation The rangehood works with . . . air recirculation: . . . air extraction: (requires a conversion kit and charcoal The air is drawn in and cleaned by the filters: see "Technical Data") grease filters and directed outside. The air is drawn in and cleaned first by If the on-site ventilation system does the grease filters and then by the...
  • Page 13: Operation

    Operation Joystick To select a power level ^ Press the joystick repeatedly to the This is used to operate the fan settings and the lighting. right to select a higher power level, and to the left to select a lower power To switch the fan on level.
  • Page 14: Automatic Switch-Off Of The Intensive Setting

    Operation Run-on option Automatic switch-off of the Intensive setting It is advisable to run the fan for a few You can set the Intensive setting so that minutes after cooking has finished to it only runs for 10 minutes before neutralise any lingering odours in the air, whether you are using air extraction reverting automatically to level III.
  • Page 15: To Switch The Cooktop Lighting On

    Operation To switch the cooktop lighting on To switch the cooktop lighting off ^ Press the joystick again once to the The cooktop lighting can be switched on and off independently of the fan. rear or to the front to switch it off. Safety cut-out Should the rangehood be left on, the fan will switch off automatically after 10...
  • Page 16: Filter Operating Hours Counter

    Operation Filter operating hours counter Reading the grease filter operating hours counter The number of hours the appliance has been in operation is stored in memory. To check the percentage of time set already used: The operating hours counter tells you ^ Switch the fan on with the joystick.
  • Page 17 Operation Altering the grease filter operating hours counter The operating hours counter for the grease filter is set at the factory for 30 hours. This can be lengthened or shortened to suit the type of cooking you do. You can choose 20, 30, 40 or 50 hours.
  • Page 18 Operation Activating and altering the charcoal filter operating hours counter (in recirculation mode) The charcoal filters must be fitted for the rangehood to be used in recirculation mode. On delivery, the operating hours counter for the charcoal filter is deactivated. For recirculation mode, the operating hours counter needs to be set to suit ^ Use the joystick to select the time...
  • Page 19 Operation Resetting the charcoal filter Reading the charcoal filter operating operating hours counter hours counter To check the percentage of time set already used: ^ Switch the fan on with the joystick. The indicator lamp for the charcoal filter control will light up after the rangehood has operated for the number of hours set.
  • Page 20: Cleaning And Care

    The re-usable metal grease filters in the order through your Miele Chartered appliance remove solid particles Agent, from Miele or via the internet at (grease, dust, etc.) from the kitchen www.miele-shop.com. vapours, preventing soiling of the rangehood.
  • Page 21 65°C programme, ensuring the spray arm is not obstructed. If a Miele dishwasher is being used, select the Sensor wash programme. ^ Use a mild dishwasher detergent.
  • Page 22: Fitting And Replacing The Charcoal Filters

    DA 2250, DA 2270: 2 charcoal filters DA 2210: 4 charcoal filters New filters can be purchased from your Miele Chartered Agent or from Miele. See back cover for contact details, and "Technical data" for the model number of the filter.
  • Page 23 Cleaning and care Always replace the charcoal filters im- mediately if – the indicator lamp for the charcoal filter control lights up, – they are no longer effective in absorbing kitchen odours. They should, however, be replaced at least every 6 months. Used charcoal filters can be disposed of with the normal household waste.
  • Page 24: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp Before any cleaning or maintenance work is carried out, disconnect the rangehood from the mains supply. Ensure that: – it is switched off at the isolator, or – it is switched off at the wall socket and the plug removed, or –...
  • Page 25: After Sales Service

    – your Miele Chartered Agent or – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
  • Page 26: Appliance Dimensions

    Appliance dimensions...
  • Page 27: Safety Distance Between Cooktop And Rangehood

    – 650 mm above an open grill or deep fat fryer. – 650 mm above gas cooktops. If this rangehood is installed above a Miele Wok CS 1028 CombiSet appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the rangehood.
  • Page 28: Installation

    Installation Fitting the non-return flap (not needed for recirculation mode) ^ Place the appliance in the cut-out from below and align it. ^ Secure the rangehood by the frame ^ If a non-return flap is not present in using 3.5 x 16 mm screws. the venting system, the non-return flap supplied must be fitted onto the exhaust socket in the motor unit.
  • Page 29 Installation ^ See "Connection for air extraction" for Preparation for extraction further instructions on fitting the ducting. ^ DA 2210: The rangehood has two exhaust connections for use with two 150 mm diameter exhaust hoses. A Y- adapter is supplied with the rangehood.
  • Page 30 For this, conversion kit DUU 151 (available from your Miele Chartered Agent or Miele ) is required. One conversion kit is required for the DA 2250 and 2270, and two kits for the DA 2210.
  • Page 31 SW 9 spanner. Do not turn the spanner. Joystick extension The joystick can be extended if required (special accessory - Miele DBV 100). 1. Screw the spring into the holder and tighten by hand. Whilst doing so, counterhold the joystick with an SW 9 spanner.
  • Page 32 Installation Electrical connection ^ If the rangehood is to be connected to an external motor (EXT models): Use the connection cable with 6 pole plug to connect the rangehood and the external motor. ^ Connect the appliance to the mains via a fused socket.
  • Page 33: Connection For Air Extraction

    Connection for air extraction – Only use smooth pipes or flexible Important: To avoid the danger of hoses made from non-flammable toxic fumes, please observe the materials for the extraction ducting. Warning and Safety instructions. – When using an external motor, make This is especially crucial when using sure that the exhaust ducting is the rangehood at the same time as...
  • Page 34: Condensate Trap

    Connection for air extraction Condensate trap – Where ducting is horizontal, it must be laid to slope away at at least 1 cm (optional accessory) per metre. This is to ensure that condensate cannot drain back into the rangehood. – If the exhaust air is to be ducted into the open air, the installation of a telescopic wall vent or roof vent (available as an optional accessory)
  • Page 35: Silencer

    Connection for air extraction Silencer ...with air extraction: (DASD 150 optional accessory) The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise). For this reason, the silencer must be positioned as close as possible to where the ducting leaves the building a.
  • Page 36: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation, an additional means of undertaken by a suitably qualified disconnection must be provided for all and competent person in strict poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
  • Page 37: Operation With Control Module Dsm 400

    Operation with Control module DSM 400 The Miele DSM 400 control module can The components of the central be used to combine the rangehood with extraction system are not supplied as other components. standard by Miele. It enables the following: If in any doubt, the advice of a competent builder must be sought.
  • Page 38: Technical Data

    Level II....900 m DA 2250 EXT ....5.5 kg Level III .
  • Page 40 Alteration rights reserved / 4511 M.-Nr. 09 202 270 / 01...

This manual is also suitable for:

Da 2210Da 2250Da 2270Da 2270 ext