Miele DA 3160 EXT Operating And Installation Instructions

Miele DA 3160 EXT Operating And Installation Instructions

Miele ventilation hood user manual

Advertisement

Operating and installation instructions
Cooker hoods
DA 3160
DA 3180
DA 3190
DA 3160 EXT
DA 3190 EXT
en - GB
To avoid the risk of accidents
or damage to this appliance
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 07 777 490

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 3160 EXT

  • Page 1 Operating and installation instructions Cooker hoods DA 3160 DA 3180 DA 3190 DA 3160 EXT DA 3190 EXT en - GB To avoid the risk of accidents or damage to this appliance it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Contents Caring for the environment ......... . 3 Warning and Safety instructions .
  • Page 3: Caring For The Environment

    Disposal of the packing material The transport and protective packing has been selected from materials which are environmentally friendly for disposal, and should be recycled. Packaging e.g. cling film, polystyrene and plastic wrappings must be kept out of the reach of babies and young children.
  • Page 4: Warning And Safety Instructions

    The cooker hood is not intended for outdoor use. Any other usage is not supported by the manufacturer and could be dangerous. Miele cannot be held liable for damage resulting from incorrect or improper use or operation of the appliance.
  • Page 5: Technical Safety

    Warning and Safety instructions Installation, maintenance and repairs may only be carried out by a Miele authorised person in accordance with current national and local safety regulations. Repairs and other work by unqualified persons could be dangerous. The manufacturer cannot be held liable for unauthorised work.
  • Page 6 These models may only be combined with a Miele external motor. This appliance must not be used in a non-stationary location (e.g. on a ship).
  • Page 7 The Miele DSM 400 control module offers the possibility of combining other components with the cooker hood (see "Operation with Control module DSM 400").
  • Page 8: Correct Use

    Warning and Safety instructions Correct use Never use an open flame beneath the cooker hood. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the cooker hood could draw flames into the filter. Fat particles drawn into the cooker hood present a fire hazard.
  • Page 9: Correct Installation

    Safety regulations prohibit the fitting of a cooker hood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11: Guide To The Appliance

    Exhaust socket ø 150 mm Control panel Grease filter Pull-out deflector plate Hob lighting Charcoal filter (extra accessory available to order for recirculation mode) Drop-down lightshield to conceal control panel The front of the deflector plate can be fitted with a lightshield to match your kitchen furniture.
  • Page 12: Description Of The Functions

    The cleaned air is then recirculated back into the kitchen. Charcoal filters are available to order through your Dealer or the Miele Spare Parts Department or via the internet on www.miele-shop.com. (See back cover for contact details and "Technical Data"...
  • Page 13: Operation

    – / + power level indicator lamp will light up. If the cooker hood has been connected to a window contact switch via the Miele DSM 400 control module, then the fan cannot be switched on if the window is shut. The indicator lamp will flash.
  • Page 14 Operation Automatic switch-off of the Intensive setting You can set the Intensive setting so that it only runs for 10 minutes before reverting automatically to level III. ^ To set this option, both the fan and the hob lighting must be switched off and the deflector plate pushed in.
  • Page 15: Cleaning And Care

    A range of Miele branded cleaning and conditioning agents are available to order through your Miele Dealer/ Chartered Agent, the Miele Spare Parts Department or via the internet at www.miele-shop.com. Before any cleaning or maintenance work is carried out, disconnect the cooker hood from the mains supply.
  • Page 16: Grease Filter

    Cleaning and care Controls The controls may suffer discolouration or damage if soiling is left on them for too long. Remove soiling straight away. Observe the General notes on cleaning earlier in this section. Do not use stainless steel cleaning agents on the controls.
  • Page 17 Make sure that the spray arm can move freely. ^ Do not wash at more than 65° C. If a Miele dishwasher is being used, select the Sensor wash programme. ^ Use a mild dishwasher detergent. Depending on the cleaning agent...
  • Page 18: Fitting And Replacing The Charcoal Filter

    It is fitted in the canopy above the grease filter. Replacement charcoal filters can be obtained from your Dealer / Chartered Agent or the Miele Spare Parts department or via the internet on www.miele-shop.com. See back cover for contact details, and "Technical data"...
  • Page 19: Changing A Halogen Lamp

    Changing a halogen lamp ^ Pull out the deflector plate, and remove the grease filter as described earlier. ^ Switch off the fan and the lighting. Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off.
  • Page 20: Appliance Dimensions

    Appliance dimensions DA 3160 DA 3180* DA 3190* 1) The front section of the wall housing unit must be fitted with a shelf to the depth of the partition wall. 2) The partition wall in the wall unit must be removable. 3) In extraction mode: when measuring for the height of the wall housing unit and the cut-out, account must be taken...
  • Page 21 – 650 mm above gas hobs and cookers. If this cooker hood is installed above a Miele Wok CS 1028 CombiSet appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the cooker hood.
  • Page 22: Installation

    Installation Installation accessories...
  • Page 23 1 exhaust connection for exhaust ducting C 150 mm. 1 reducing collar for exhaust ducting C 125 mm. 1 non-return valve for fitting into the exhaust connection (not for recirculation mode). 2 brackets to support the appliance in the wall unit.
  • Page 24 Installation...
  • Page 25: Positioning The Appliance In The Wall Housing Unit

    Positioning the appliance in the wall housing unit To position the appliance correctly, cut the spacer strip to required depth T, and then attach it to the back of the appliance. T= Depth of carcase K minus depth of appliance G ^ The depth of appliance G depends on the lightshield being used: –...
  • Page 26 Installation ^ Screw the brackets onto the right and left inside walls of the housing unit as shown. The back edge of the brackets should align with the vertical line drawn up from the front of the spacer strip, and the lower edge aligned with the lower edge of the housing unit side wall.
  • Page 27 ^ When fitting a DA 3180 or a DA 3190 appliance into a 60 cm unit, unscrew the brackets on the deflector plate whilst it is pulled out. ^ Lift the appliance up into the housing from below, and engage in the brackets.
  • Page 28: Attaching The Lightshield

    Installation ^ Secure the front of the appliance to the floor of the housing unit from below using 4 screws (6 screws for 90 cm wide cooker hood). To avoid damaging the deflector plate when it is pulled out, care should be taken to screw the fixing screws in straight, and to ensure that the screwheads are countersunk.
  • Page 29: Aligning The Deflector Plate

    Aligning the deflector plate ^ The position of the deflector plate can be brought forward by up to 50 mm using the adjusting screws on either side of the deflector plate. Align the deflector plate to the front of the kitchen furniture units on either side.
  • Page 30: Setting Up For Extraction Mode

    Installation Setting up for extraction mode ^ If the on-site ventilation system does not have a non-return flap, then the non-return flap supplied with the appliance must be fitted in the exhaust socket in the motor unit. ^ When using C 150 mm ducting, secure the exhaust connection supplied to exhaust ducting with hose clips.
  • Page 31: Setting Up For Recirculation Mode

    For this, conversion kit DUU 151 (available from your Miele dealer or the Miele Spare Parts Dept.) is required. You will also need a charcoal filter (see “Technical data”).
  • Page 32: Connection For Air Extraction

    Connection for air extraction Important: To avoid the danger of toxic fumes, please observe the Warning and Safety instructions. This is especially crucial when using the cooker hood at the same time as another heating appliance which relies on air from the same room. The cooker hood should be installed according to local and national building regulations.
  • Page 33: Condensate Trap

    – If the exhaust air is to be ducted into the open air, the installation of a telescopic wall vent or roof vent (available as an optional accessory) is recommended. – If the exhaust air is to be ducted into a vent flue, the ducting must be directed in the flow direction of the flue.
  • Page 34: Silencer

    Connection for air extraction Silencer (optional accessory) To achieve even further reductions in noise levels, a special silencer can be fitted in the ducting system..with air extraction: The silencer not only reduces noise from the fan, but also sounds from outside (e.g.
  • Page 35: Electrical Connection

    All electrical work should be undertaken by a suitably qualified and competent person in strict accordance with current national and local safety regulations (BS 7671 in the UK). Installation, repairs and other work by unqualified persons could be dangerous, for which the manufacturer cannot be held liable.
  • Page 36: Operation With Dsm 400 Control Module

    Operation with DSM 400 control module The Miele DSM 400 control module can be used to combine the cooker hood with other components. It enables the following: Connection to a window contact switch If adequate ventilation to the room can...
  • Page 37: Connection To A Light Switch

    Operation with DSM 400 control module Connection to a light switch The control module can be used to switch on the cooker hood lighting via a light switch in the house. Installation The control module must be installed above the cooker hood housing. The control module is supplied with its own detailed operating and installation instructions.
  • Page 38: After Sales Service

    In the event of a fault which you cannot correct yourself, or if the appliance is under guarantee, please contact: – Your Miele Dealer / Chartered Agent – The Miele Service Department (see back cover for address). When contacting your Dealer or Miele, please quote the model and serial number of your appliance.
  • Page 39: Technical Data

    DA 3160 ....12 kg DA 3160 EXT ....10 kg DA 3190 .
  • Page 40 Alteration rights reserved / 1111 M.-Nr. 07 777 490 / 02...

This manual is also suitable for:

Da 3190 extDa 3160Da 3180Da 3190Da 2250 ext

Table of Contents