North Star NSC30UD1 Installation Operation & Maintenance page 21

Ultra ii computerized demand
Table of Contents

Advertisement

Ultra II
DEMAND TIMER FEATURES, SETTINGS, AND SERVICE, continued
setting: MODEL CODE, 12 OR 24 HOUR CLOCK, AND GALLONS OR LITERS MEASURE . . .
NOTE: The model code is factory set at assembly and testing. The hour clock and water measure have factory
set default values. The defaults are: 12 or 24 hour clock -- 12; Gallons or liters measure -- gallons. The model
code should never require resetting, but to check, or to set if previously omitted, read below. The defaults suit
most installations. However, to make a change, read and do the following.
MODEL CODE: The timer must have the right mod-
el code set to operate the softener correctly. The
correct code settings are:
" For model NSC30UD1 it must show A 27.
" For model NSC40UD1 it must show A- -31.
" For model NST45UD1 it must show A- -39.
" For model NST70UD1 it must show A- -68.
If A - - - is flashing in the display, do steps 2, 3, 5
and 7.
To check for the correct code setting, and to reset
if needed, do steps 1, 2, 3, 5 and 7.
12 OR 24 HOUR CLOCK: With 12 hr set, all time
displays are in standard clock time, 12:00AM to
11:59PM. If 24 hr is set, time displays are in military
time... 0100 (1:00AM) to 0000 (midnight). To change
from the 12 hr setting, do steps 1, 3, 4, 5, and 7.
GALLONS OR LITERS MEASURE: All water flow
rate and usage displays are in gallons with the de-
fault GALS setting. If reset to litErs, the same dis-
plays are shown in liters. Use steps 1, 3, 5, 6 and 7
to change.
1. Beginning from the present
time display, press and hold in
the SET button until 2:00 AM (or
as otherwise set), and RE-
CHARGE TIME begins to flash.
2. Press and hold in the SET
button again. Either A -- -- -- or
a previously set code will ap-
pear. If setting is needed, use
the up or down button to set
model code, as needed.
3. Press SET to to select and move to next screen.
4. 12 hr flashes along with
TIME. To change the display to
24 hr, use the up button. Use the
down button to reset to 12 hr.
5. Press SET to select and move to next screen.
6. GALS flashes, along with
GALLONS. Use the up button
to change to the liter setting.
Use the down button to return to
the gallon setting.
7. Press the SET button a final time to return to the
present time display.
AM
RECHARGE
TIME
TIME
GALLONS
LITERS
21

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nsc40ud1Nst45ud1Nst70ud1

Table of Contents