North Star NSC30UD1 Installation Operation & Maintenance page 18

Ultra ii computerized demand
Table of Contents

Advertisement

Ultra II
DEMAND
NOTE: SEE PAGES 11 and 12 TO SET THE TIMER TO THE CORRECT TIME OF DAY, AND WATER HARDNESS NUMBER.
NORMAL OPERATION, TIMER DISPLAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
During normal operation, the
present time of day, and AM or
PM, show in the time display
area. The demand computer
determines when a regenera-
tion
is
needed.
Then,
regeneration will begin at the
next regeneration start time
feature: OTHER DATA DISPLAYS
With repeated presses of the DATA button, you can
scan through four displays of operational informa-
tion. This data appears in the bottom portion of the
display area. These are:
CAPACITY (remaining) -- This is
the percentage of water soften-
ing capacity remaining. Immedi-
ately after a regeneration, 100%
shows. Then, as water is used,
the percentage decreases until
the next regeneration. During
regenerations, the percentage
increments upward.
NOTE: Zero (0%) shows until after the first regen-
eration begins, after connecting to electrical power.
*
If preferred, you can set the timer to show the reading in liters instead of gallons, see page 21. If gallons
today, or average daily gallons exceeds 1999, a (x 10) indicator appears. This means you must multiply the
number shown times 10.
feature: OPTIONAL RECHARGE CONTROLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sometimes, a manually started regeneration (re-
charge) may be desired, or needed. Two examples
are:
... You have used more water than usual (house
guests, extra washing, etc.) and you may run out of
soft water before the next regeneration.
18
TIMER FEATURES, SETTINGS, AND SERVICE
PM
a
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WATER MANAGEMENT SYSTEM
%
CAPACITY
(2:00AM or as you set it).
RECHARGE NOW will flash
until the regeneration is over.
The display will also show the
current cycle in the regenera-
tion process. When the valve is
in transition between cycles,
both indicators flash.
FLOW RATE, GPM* -- When
using soft water, this display
shows the gallon per minute
flow rate passing through the
softener. Zero shows if water is
not in use.
*
GALLONS
TODAY -- Each
day, beginning at midnight, the
timer keeps a running count of
the total gallons of water pass-
ing through the softener.
AVERAGE DAILY GALLONS
-- The figure displayed is the av-
erage gallons of water used by
the household each day, over
the past seven day period.
... You did not refill the storage tank with salt before
it was all gone.
Use one of the following features to start a regenera-
tion immediately, or at the next preset regeneration
start time.
AM
Fill
RECHARGE NOW
WATER MANAGEMENT SYSTEM
GPM
FLOW RATE
WATER MANAGEMENT SYSTEM
GALLONS TODAY
*
WATER MANAGEMENT SYSTEM
AVG DAILY GALLONS
continued