Control mode
Terminal 4 function according to control
Real Sensorless Vector Control (Pr. 800 = 12), Vector Control (Pr. 800 = 2)
Pr. 858 Setting
Speed control (MC signal-OFF)
0 (initial value)
Speed command (AU signal-ON)
1
4
9999
Pr. 858 Setting
Speed control (MC signal-OFF)
0 (initial value)
Speed command (AU signal-ON)
1
4
9999
Pr. 858 Setting
Position control (MC signal-OFF)
0 (initial value)
1
4
9999
⎯ :No function
REMARKS
⋅ Switching between speed control and torque control is always enabled independently of whether the motor is at a stop or
running or the DC injection brake operation (pre-excitation).
⋅ Speed control/position control switchover and torque control/position control switchover is made when frequency drops to the
Pr. 865 Low speed detection, and not switched during motor operation.
CAUTION
⋅ Changing the terminal assignment using Pr. 178 to Pr. 189 (input terminal function selection) may affect the other functions. Please
make setting after confirming the function of each terminal.
♦ Parameters referred to ♦
Advanced magnetic flux vector control
Real sensorless vector control, vector control (speed control)
Real sensorless vector control, vector control (torque control)
Vector control (position control)
Pr. 178 to Pr. 189 (input terminal function selection)
Pr. 450 Second applied motor
Pr. 804 Torque command source selection
Pr. 807 Speed limit selection
Pr. 810 Torque limit input method selection
Pr. 858 Terminal 4 function assignment, Pr. 868 Terminal 1 function assignment
90
Magnetic flux command
Torque limit (Pr. 810 = 1)
Vector Control (Pr. 800 = 4)
Magnetic flux command
Torque limit (Pr. 810 = 1)
Vector Control (Pr. 800 = 5)
Magnetic flux command
Torque limit (Pr. 810 = 1)
Refer to page 140
Refer to page 124
Refer to page 222
Refer to page 179
Refer to page 117
Refer to page 119
Refer to page 94
Torque control (MC signal-ON)
Speed limit (AU signal-ON)
Magnetic flux command
Position control (MC signal-ON)
Magnetic flux command
Torque limit (Pr. 810 = 1)
Torque control (MC signal-ON)
Speed limit (AU signal-ON)
Magnetic flux command
Refer to page 91
Refer to page 113
Refer to page 274