PROGRAMS AND CONTROl UNIT

5.6 Settings

DW70.1
L2
L12
L1
L4
PROGRAM
L11
S1
S3
S4
L10
L5
L6
Variant 1
Panel type DW70.1, L = LED, S = Push button
Variant settings
When the power is switched on for the first time
after replacing the control unit, the variant settings
menu is displayed.
l1 flashes: Variant 1 see above, with two options
(temp, dry).
l4 flashes: Variant  see above, with one option
(temp).
1.
Press the Program button (S1) until either L1
or L flashes.
.
Confirm your selection by pressing Start (S).
(The program automatically returns to the
main menu.)
To return to the variant settings menu:
1.
Turn off the main power switch (I/0)
.
Wait at least 5 seconds
.
Press and hold the Program and Start buttons
(S1 & S)
.
Switch off the main power switch (I/0)
5.
Release the Program and Start buttons (S1 &
S)
.
Press Start (S) three times within 5 seconds.
Use the Program button (S1) to select the vari-
ant
7.
Confirm your selection by pressing Start (S).
The program returns to the main menu.
Water hardness setting
Activating the settings menu
1.
Turn off the main power switch (I/0)
.
Wait at least 5 seconds
.
Press and hold the Start button (S)
.
Switch off the main power switch (I/0)
5.
Release the Start button (S); L7 starts flashing
.
Use the Program button (S1) to select the de-
sired water hardness
L2
L7
L1
PROGRAM
START
L8
S1
STOP
S2
S4
L9
L6
Variant
L12
L7
L4
START
L8
L11
STOP
S2
L10
L9
L5
Setting: Water hardness
[°dh] (German water hardness scale)
All LEDs unlit
(also applies to machines without water softener)
L1 lit
L1- lit
L1- lit
L1- lit
L1-5 + L11 lit
L1- + L11 + L1 lit
Confirm your selection by pressing Start (S). The
program returns to the main menu.
Total reset
To reset the machine to its factory settings.
1.
Turn off the main power switch (I/0)
.
Wait at least 5 seconds.
.
Press and hold the Program button (S1)
.
Switch off the main power switch (I/0)
5.
Release the Program button (S1).
L1 and L flash during the reset process. The ma-
chine will reset various settings, although not water
hardness, and then automatically return to the main
menu. Detects the presence of a pressure sensor.
0-5
-8
9-1
15-19
0-9
0-
5+
19