Orion Network Pro 1500 RTX User Manual

Line interactive ups

Advertisement

USER GUIDE

Network Pro 1500 RTX
Network Pro 2200 RTX
Line Interactive UPS
Uninterruptible Power Supply System

Advertisement

Table of Contents
loading

Summary of Contents for Orion Network Pro 1500 RTX

  • Page 1: User Guide

    USER GUIDE Network Pro 1500 RTX Network Pro 2200 RTX Line Interactive UPS Uninterruptible Power Supply System...
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for NP1500RTX & NP2200RTX that should be followed during installation and maintenance of the UPS and batteries. Please read all safety and operating instructions before operating the UPS. Adhere to all warnings on the unit and in this manual.
  • Page 3: Table Of Contents

    CONTENTS   1. INTRODUCTION························································································································· 3   2. SAFETY WARNING ····················································································································· 3   2.1 D ······················································································ 4 ESCRIPTION OF OMMONLY YMBOLS   3. INSTALLATION ·························································································································· 5   3.1 I ··················································································································· 5 NSPECTION OF   3.2 U ············································································································· 5 NPACKING THE ABINET  ...
  • Page 4: Introduction

    1. Introduction This line-interactive UPS series is a compact pure sine wave UPS designed for essential applications and environments, such as servers, workstations, and other networking equipment. This model is available in the output rating of 1500VA & 2200VA and is designed to protect your sensitive electronic equipment against power problems including power sags, spikes, brownouts, line noise and blackouts.
  • Page 5: Description Of Commonly Used Symbols

    CAUTION:  Batteries can present a risk of electrical shock or burnt from high short-circuit current. Observe proper precautions. Servicing should be performed by qualified service personnel knowledgeable of batteries and required precautions. Keep unauthorized personnel away from batteries.  Proper disposal of batteries is required. Refer to your local codes for disposal requirements. ...
  • Page 6: Installation

    3. Installation 3.1 Inspection of Unit Inspect the UPS upon receiving. If the UPS is apparently damaged during the shipment, please keep the box and packing material in original form for the carrier and notify the carrier and dealer immediately. 3.2 Unpacking the Cabinet To unpack the system: 1.
  • Page 7 3. Pull out the LCD box and rotate it in a clockwise direction to 90 degree and then push it back in the front panel.  Rack-mount setup The series can be installed in 19 inches racks. Both the UPS and external battery enclosure need 2U of valuable rack space.
  • Page 8 3. Slide in the UPS into the rack rail and lock it in the rack enclosure. 4. Tighten the screw, and the load can then be connected...
  • Page 9: Ebm Installation (Optional)

    3.4 EBM Installation (Optional)  Connecting the EBM in Tower form: 1. Hold the UPS and EBM vertically and place two UPS stands with the extend part at each end of the tower. 2. Tighten the screw on the metal sheet for stabilization 3.
  • Page 10: Ups Initial Startup

    2. Connect EBM port C to UPS port D with one of the accessory wire. 3.5 UPS Initial Startup To start up the UPS: 1. Verify that the internal batteries are connected. If optional EBMs are installed, verify that the EBMs are connected to the UPS.
  • Page 11: Operation

    4. Operation 4.1 Display Panel The UPS has a four-button graphical LCD with dual color backlight. Standard back-light is used to light up the display with black text and a blue background. When the UPS has a critical alarm, the backlight changes the background to red.
  • Page 12 Note: Ensure the battery is fully charged during line mode when conducting functional tests. Note: A list of events shown as below is not able to disable alarm buzzer: Low Battery, Fan Failed, Fan Fault Time Out, and Overheat. Note: User can disable the alarm buzzer when it’s sounding, but an alarm will still sound when a new alarm event is encountered.
  • Page 13  UPS Status Display String Description: The following table shows the description of the LCD display string. Table4. UPS Status Display String LCD Display String Description STbY UPS work at Standby mode IPVL Input voltage is too low IPVH Input voltage is too high IPFL Input frequency is too low IPFH...
  • Page 14: Operating Mode

    4.2 Operating Mode  Normal range mode: Under Input mode the UPS accepts AC input voltage range for +20% ~ -25%.  Generator mode: Under generator mode, the low frequency transfer point can go as low as 40Hz and as high as 70Hz before being transferred to battery mode.
  • Page 15: Communication Port

    5. Communication Port 5.1 RS-232 and USB Communication Ports To establish communication between the UPS and a computer, connect your computer to one of the UPS communication ports using an appropriate communication cable. When the communication cable is installed, power management software can exchange data with the UPS. The software polls the UPS for detailed information on the status of the power environment.
  • Page 16: Network Management Card (Optional)

    EPO Connector 5.3 Network Management Card (Optional) Network Management Card allows the UPS to communicate in a variety of networking environments and with different types of devices. The UPS series has one available communication slot for NMC card or other optional card to achieve remote management of the UPS through internet/ intranet.
  • Page 17: Replacing Ups Internal Batteries

    6.4 Replacing UPS Internal Batteries Follow the steps and Charts as below to replace batteries: 1. Take off the LCD box, and remove the screws. 2. Slide and pull the front panel leftward and then take it off. 3. Disconnect the cable from the UPS and battery pack. 4.
  • Page 18: Testing New Batteries

    6.5 Testing New Batteries For a battery test, please check: The batteries must be fully charged.  The UPS must be in Normal mode with no active alarms.  Don’t take on/off the load.  To test batteries: 1. Connect the UPS to utility power for at least 48 hours to charge the batteries. 2.
  • Page 19: Network Pro Rtx Specification

    7. Network Pro RTX Specification 7.1 Specification Table 7. Electrical Specification NP1500RTX NP2200RTX Model 1500VA/1350W 2000VA/1800W Rated Capacity VA/Watt 1500VA/1350W 2200VA/1980W Maximum Capacity VA/Watt 89-144VAC Input voltage range Input 50/60Hz ±5Hz for Normal Mode Frequency range 40-70Hz for Generator Mode 120VAC Voltage Voltage Regulation...
  • Page 20 Table 8. Indicators and Audible alarm NORM---normal mode AC Mode Show “bATT” and sounding every 4 seconds Backup Mode LCD showing Load/Battery Level Indicator LCD show red screen and “ **** ” UPS Fault LCD show red screen and “ OVLd ” Overload LCD show red screen and “...
  • Page 21: Rear Panels

    7.2 Rear Panels The UPS rear panel description table and pictures are shown below: Function AC Output External battery connector SNMP Port AC Input RS232 / Dry-Contact Communication Port USB Port Earth Line Port NP2200RTX REAR PANEL LAYOUT NP1500RTX REAR PANEL LAYOUT The EBM rear panel description table and picture are shown below: Function (36V &...
  • Page 22: Trouble Shooting

    8. Trouble Shooting 8.1 Audible Alarm Trouble Shooting Indication Cause Solution Sounding every 4 seconds The UPS is on battery mode Check the input voltage Sounding every Second and The battery voltage is low Save your work and turn off your equipment “bATL”...
  • Page 23: Product Registration

    For critical applications, immediate replacement may be available. Product Registration Product Registration is required to activate the load protection guarantee for your Orion Power UPS. Registering your product also allows Orion Power Systems to communicate product updates, features, and warranty issues.

This manual is also suitable for:

Network pro 2200 rtx

Table of Contents