Parameter Settings - Pfaff 571 Instruction Manual

Hide thumbs Also See for 571:
Table of Contents

Advertisement

11

Parameter settings

.09
Following parameters can be set on the control panel using the display:
Group Parameter Significance
6
7
601
Cut
l = yes
ll = no
607
Max. speed
609
Cutting speed 1
660
Bobbin thread monitoring
0 = without
1 = with sensor
2 = with stitch counting
700
Needle position 0
Needle reference position
701
Angle setting
I = Synchronizer setting with
balance wheel
II = Synchronizer setting with
" + " and " - " keys
702
Needle position 1 (needle lowered)
703
Needle position 2
(take-up lever raised)
705
Needle position 5
(end cutting signal 1)
707
Needle position 9
(Start thread tension release)
For more displays and information see the motor instruction manual.
Adjustment
Setting
Standard value
100 - 2800
2800
30 - 300
180
0 - 2
0 - 127
0 - 127
40
0 - 127
117
0 - 127
90
0 - 127
100
l
0
l
11 - 63

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

574591

Table of Contents