11
Releasing the tension
.07.08
Requirement
When the magnet is activated, tension discs 3 must be at least 0.5 mm apart.
Fig. 13 - 51
Activate the magnet.
Detach the tension bearing plate 1 and adjust pressure plate 2 in accordance with the
requirement.
0.5 mm
3
It is possible to set the time for releasing the tension with the parameter
functions, see Chapter 11.10 Parameter settings.
Adjustment
1
2
61-043