Information Display

To Set the 7 Day Programmable Ice Level

There are four times and levels available for each day of the week.
Use Up or Down Arrow keys to scroll to PGM Bin Level screen. When the P
in PGM is underlined, press and release the Enter key.
Bin Level Ctrl is on the screen. If it reads Off, push and release the down
arrow button to begin programming.
If Bin Level Ctrl is On, push and release the SEL
button. From On, push the Down arrow key to turn
Off. The control must be set to OFF to adjust bin
level. Push Enter and Down to get to the first
programming menu.
Monday Time 1 will show on the screen. Press and release the SEL key to
begin setting Monday Time 1. Set Monday Time appears in the display.
Change Monday Time 1: 12:00 AM might be displayed. To adjust, push the
SEL button to position the underline mark under the character to be changed.
Push and release the up or down arrow key to change the number or letter
one time. Repeat pushing the SEL button to move the underline and repeat
pressing the up and down arrow buttons to change the time.
Push Enter once to change the screen back to Monday Time 1. Push Down
once to get to the level reading.
Change Monday Level 1: Monday Level 1 is in the
display. Push SEL once to display Set Monday Level 1.
Rotate the knob one click at a time until the desired
level appears. A delay is normal.
Note: smaller numbers = higher ice level.
Push Enter one time to set the level. "Off" means the switch is set for
maximum ice level.
Push the Down arrow to go to Monday Time 2, and set that time using SEL
and arrow buttons as in Change Monday Time 1 above. Push Enter once to
set it and change back to Monday Time 2. Push the down arrow button to go
to Monday Level 2 and change that level using the SEL button and the knob
as in Change Monday Level 1 above. Push Enter to set that level.
Repeat for all time and level settings.
When done, push ESC to return to the PGM Bin Level screen. When the P in
PGM is underlined, press and release Enter.
Bin Level Ctrl will show on the screen. Push and release the SEL button.
Push and release up arrow key to change the setting from Off to On.
Push and release Enter and ESC when done.
Bin Level Ct
On
Set Bin Level Ct
Off
August 2011
Page 12
Setup
PGM Bin Level
Bin Level Ct
Off
Monday Time 1
01:30 AM
Set Monday Time
12:00 AM
Monday Time 1
02:30 AM
Monday Level 1
9 inches
Set Monday Level
14 inches
Monday Time 2
11:00 AM
Monday Level 2
9 inches
Set Monday Level
14 inches
Setup
PGM Bin Level
Bin Level Ct
Off
Set Bin Level Ct
On

Advertisement