Is the Link LED lighted?
Are the network settings correct?
If output is impossible even though the link LED is on, make sure the IP address and other settings are cor-
rect. The settings on both the machine and the computer must be appropriate. Redo the settings, checking
to ensure that the IP address doesn't conflict with the IP address for another device on the network, that the
port setting for the software RIP specifies the IP address set on the machine, that the settings have no typing
errors, and for other such problems.
 "Setup Guide," p. 163, "Viewing Information about the System of This Machine"
Did the software RIP end abnormally?
Make sure the software RIP is running correctly, then switch the sub power switch off and back on.
 "Roland VersaWorks Quick Start Guide"
Is the temperature of the room too low?
Use the machine in an environment where the temperature is 20 to 32°C (68 to 90°F).

Cannot cut off the media

Is the separating knife mounted?
If the separating knife is not mounted, you cannot cut off the media.
 P. 117, "Replacing the Separating Knife"

The Media Take-up System Doesn't Run

Is the take-up unit cable connected?
Connect the take-up unit cable to the machine. To perform take-up automatically when output is in progress,
also make the setting for the AUTO switch.
 "Setup Guide," P.81 "Use Conditions of the Media Take-up System"
If the Link LED for the Ethernet connector is not lighted, it
means that a correct connection to the network has not
been made. Make sure the network routing is suitable. Try
connecting the computer and the machine to the same
Link LED
hub, or connecting them directly using a crossover cable.
If this makes it possible to perform output, it means the
problem is in the network itself.