ADJUSTMENTS & SETTINGS (SERVICE MENU)

RS232C SET RS-232C signal setting display

This menu does not work when selecting THERMAL : ON or MULTI : OFF(PRN
SELECT).
BAUD RATE
Set the baud rate of RS-232C.
Set the baud according to the connecting device.
COMMAND TYPE
Sets the command type of RS-232C.
Selects the command type of RS-232C to control this unit.
Select "A" for normal setting. Depending on the connected equipment, select "B"
or "C".
RESPONSE
Selects whether this unit sends RS-232C response to the host
computer or not.
OFF
Does not send response.
ON
Sends normal response.
ERR RES OK
Selects the response code when an error occurs.
NOR
Sends the regular response.
ILL
Sends "job end" even if ILLEGAL error occurs.
INV
Sends "job end" even if INVALID error occurs.
ALL
Sends "job end" when any error occurs.
NO DSR
Sets to use 232C, DSR and DTR.
Sets "NO DSR" according to the connecting device.
OFF
Uses NO DSR.
ON
Does not use NO DSR.

REMOTE SET Remote signal setting display

BUSY LEVEL
Selects the level of BUSY signal from the remote terminals 1 and 2
on the rear panel.
LOW
The VCP cannot accept the remote input signal when the signal is
"LOW".
HIGH
The VCP cannot accept the remote input signal when the signal is
"HIGH".
The default setting is "HIGH".
BUSY 1,2 SELECT Selects when the BUSY signal is outputted from the remote terminals
1 and 2 on the rear panel.
PRINTING
Outputs BUSY signal during printing.
MECHA ERR
Outputs BUSY signal when a mechanical error occurs in this unit or
IC chip is not installed. BUSY signal is also outputted when the printing
mechanism is pulled out or the menu is displayed on the monitor.
MEDIA ERR
Outputs BUSY signal when an error for paper or ink sheet occurs.
MEMORY STOP Outputs BUSY signal when MEMORY button is not functioning.
STROBE 1V
After outputting BUSY signal, memory is taken in by waiting to 1 vertical
period.
STROBE 2V
After outputting BUSY signal, memory is taken in by waiting to 2 vertical
periods.
REMAINING
Outputs BUSY signal while the remains of ink sheet becomes the
value set in REMAINING Q'ty.
When either STROBE 1V or STROBE 2V is set to OFF, the other is available for
setting.
52
RS232C SET
BAUD RATE
1200/2400/4800/9600
COMMAND TYPE
A/B/C
RESPONSE
OFF/ON
ERR RES OK
NOR/ILL/INV/ALL
NO DSR
OFF/ON
REMOTE SET
BUSY LEVEL
LOW/HIGH
BUSY1,2 SELECT
PRINTING
OFF/1/2/1&2
MECHA ERR
OFF/1/2/1&2
MEDIA ERR
OFF/1/2/1&2
MEMORY STOP
OFF/1/2/1&2
STROBE 1V
OFF/1/2/1&2
STROBE 2V
OFF/1/2/1&2
REMAINING
OFF/1/2/1&2