Interval Set - Mitsubishi Thermal Digiplater User Manual

Table of Contents

Advertisement

3.3.10 Interval Set

We recommend cleaning Thermal Head by the lapping film (3M Lapping film Aluminum
Oxide 261X, Grain size/ 3 micron (pink) sheet) at once a 50 plates.
However, it needs to stop every 50 plats or anytime you selected automatically when
making the plate more than 50 plates. This function allows doing it and gives the
message when stopping. The default setting is off.
• This mode use particular counter.
• The counter is reset whenever you turn off THERMAL DIGIPLATER.
• It's shown "print restart" in LCD and if you press the enter button, the counter is
reset.
1.
In the ready state, press the menu button
once, press the + button 9 times, and
display "Interval set" on the LCD.
2.
Press the enter button to display current
setting value.
・The factory setting is "0".
3.
Press the + , MENU or -, Loading button to
change the setting of the interval number.
[Useful tip]
Pressing the + or - button repeatedly changes the message on the LCD as
shown below.
[Plate Size]
[Size Set]
[Remains Sw]
【 【 【 【 Useful tip】 】 】 】
It can be set from 0 to 500, in increments of 10.
+ button: +10
menu button: +100
if you set "0", this function off.
Chapter 3
Interval set
[Density]
[Firmware Version]
[Platen Cleaning]
[Manage Count]
LCD message cycle when[+]is pressed repeatedly
LCD message cycle when[-]is pressed repeatedly
Interval
Interval
- button: -10
loading button: -100
-39-
Use of Operation Panel
[Plate]
[Counter]
[Interval Set]
[Adjust Plate]
0
50