A
PPENDIX
(for restricted power supply condition mode only)
INFORMATION
When booster heater and domestic hot water schedule
timers are used, make sure they are enabled during the
period that space heating/cooling is disabled.
Example pattern:
0:00
1:00
2:00
A
A Space heating/space cooling
B Domestic water heating
C Booster heating
EKHBH/X008BB
Indoor unit and options for air to water heat pump system
4PW62571-1A – 05.2011
3:00
4:00
5:00
6:00
A
B
C
CAUTION
In case the disinfection function is required, the schedule
timer for domestic water heating and booster heating must
be used. If the domestic water heating and booster heater
are not stopped, than this disinfection can not start.
Disinfection example pattern (refer to
7:00 ~
function" on page
23:59
Pattern 1:
Pattern 1 is an example schedule timer for domestic hot
water production.
Mon
0:00
Pattern 2:
Pattern 2 is an example schedule timer for disinfection
function
production.
Mon
0:00
A
14).
Tue
Wed
Thu
1:00
2:00
3:00
4:00
A
B
C
A Space heating/space cooling
B Domestic water heating
C Booster heating
in
combination
with
Tue
Wed
Thu
1:00
2:00
3:00
4:00
B
C
D
A Space heating/space cooling
B Domestic water heating
C Booster heating
D Disinfection function
"[2] Disinfection
Fri
Sat
Sun
7:00 ~
5:00
6:00
23:59
A
domestic
hot
water
Fri
Sat
Sun
7:00 ~
5:00
6:00
23:59
A
Operation manual
26