OPERATION MANUAL

Indoor unit and options for air to water heat
pump system
EKHBH008BB3V3
EKHBH008BB6V3
EKHBH008BB6WN
EKHBH008BB6T1
EKHBH008BB9WN
EKHBH008BB9T1
EKHBX008BB3V3
EKHBX008BB6V3
EKHBX008BB6WN
EKHBX008BB6T1
EKHBX008BB9WN

Advertisement

Table of Contents

Troubleshooting

loading

Summary of Contents for Daikin EKHBH008BB3V3

  • Page 1: Operation Manual

    OPERATION MANUAL Indoor unit and options for air to water heat pump system EKHBH008BB3V3 EKHBH008BB6V3 EKHBH008BB6WN EKHBH008BB6T1 EKHBH008BB9WN EKHBH008BB9T1 EKHBX008BB3V3 EKHBX008BB6V3 EKHBX008BB6WN EKHBX008BB6T1 EKHBX008BB9WN...
  • Page 2: Table Of Contents

    Indoor unit and options for air to water EKHBH008BB*** Operation manual EKHBX008BB*** heat pump system 1. D ONTENTS EFINITIONS Page 1. Definitions.................. 1 1.1. Meaning of warnings and symbols..........1 1.1. Meaning of warnings and symbols 1.2. Meaning of used terms ..............2 2.
  • Page 3: Meaning Of Used Terms

    Person who is owner of the product and/or operates the product. pumps. This unit is designed for wall mounted indoor installation. The unit can be combined with Daikin fan coil units, floor heating Service company: applications, low temperature radiators, Daikin domestic water Qualified company which can perform or coordinate the required...
  • Page 4: Scope Of This Manual

    Domestic hot water tank (option) PERATING THE UNIT An optional domestic hot water tank can be connected to the indoor unit. The domestic hot water tank is available in 2 types: 4.1. Introduction ■ tank with built-in electrical booster heater (EKHW*) in 3 different sizes: 150, 200 and 300 litre, The heat pump system is designed to provide you a comfortable ■...
  • Page 5: Operating The Digital Controller

    4.2. Operating the digital controller 4.3. Name and function of buttons and icons Operating the EKHB* unit comes down to operating the digital controller. CAUTION Never let the digital controller get wet. This may cause an electric shock or fire. Never press the buttons of the digital controller with a hard, pointed object.
  • Page 6 ACTION ICONS 26. DOMESTIC WATER HEATING BUTTON These icons indicate the programming actions for each day of This button enables or disables heating of the domestic water. the schedule timer. This button is not used when the domestic hot water tank is not installed.
  • Page 7: Setting Up The Controller

    4.5. Description of the operation modes 34. QUIET MODE BUTTON This button enables or disables quiet mode. If the controller is set in permission level 2 or 3 (refer to "5. Field Space heating operation ( ) settings" on page 13), the quiet mode button will not be operable.
  • Page 8: Powerful Domestic Water Heating Operation

    Only for [4-03]=4 or 5 Quiet mode operation ( In this mode, the indoor unit will heat up the domestic hot water tank. Quiet mode operation means that the outdoor unit works at reduced There are several modes for heating up the domestic water tank: capacity so that the sound produced by the outdoor unit drops.
  • Page 9: Schedule Timer Operation

    Switch on the unit by pushing the button. Displaying actual temperatures The operation LED lights up. Push the button for 5 seconds. icon and the entering water temperature are displayed. INFORMATION The icons are flashing. When the unit is connected to an external room Use the buttons to display: thermostat, buttons...
  • Page 10: Programming And Consulting The Schedule Timer

    What can the schedule timer do? What can the schedule timer NOT do? The schedule timer allows the programming of: The schedule timer can not change the operation mode from space heating to space cooling or vice versa. Space heating (refer to "Programming space heating or domestic water heating"...
  • Page 11: Programming

    Programming Programming space heating or domestic water heating Programming space heating or domestic water heating is carried out as follows: INFORMATION Returning to previous steps in the programming procedure without saving modified settings is done by pressing the button. Press the button.
  • Page 12 Programming space cooling, quiet mode, or booster heater Programming space cooling, quiet mode, or booster heater mode mode is carried out as follows: INFORMATION Returning to previous steps in the programming procedure without saving modified settings is done by pressing the button.
  • Page 13: Consulting Programmed Actions

    To copy programmed actions to the next day, proceed as follows: Consulting programmed actions Press the button. Consulting space heating or domestic water heating actions The actual mode is blinking. Consulting space heating or domestic water heating is carried out as Use the buttons to select the mode you want follows.
  • Page 14: Field Settings

    Save the new value by pressing the button. IELD SETTINGS Repeat step 2 through 4 to change other field settings as required. NOTICE When finished, press the button to exit FIELD SET MODE. The default values mentioned in "Field settings table" on page 18 are the values from factory.
  • Page 15 [1] Weather dependent set point [2] Disinfection function The weather dependent set point field settings define the parameters Applies only to installations with a domestic hot water tank. for the weather dependent operation of the unit. When weather The disinfection function disinfects the domestic hot water tank by dependent operation is active the water temperature is determined periodically heating the domestic hot water to a specific temperature.
  • Page 16 (2) or reheat is disabled (0) (>60°C). In that case Daikin suggests to install a shunt pump and a heater element parallel on the domestic hot water tank according to ■...
  • Page 17 [9-05~9-08] Automatic setback function INFORMATION Setback function provides the possibility to lower the water ■ Make sure the domestic water is only heated up to the temperature during space heating. The setback function can for domestic hot water temperature you require. instance be activated during the night because the temperature Start with a low domestic hot water storage demands during night and day are not the same.
  • Page 18 [d] Local shift value weather dependent Local shift value weather dependent The local shift value weather dependent field setting is only relevant in case weather dependent set point (see field setting "[1] Weather dependent set point" on page 14) is selected. ■...
  • Page 19: Field Settings Table

    Field settings table Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit User permission level User permission level — Weather dependent set point Low ambient temperature (Lo_A) –10 –20~5 °C...
  • Page 20 Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Installation related setting Installation related setting Installation related setting Not applicable. Do not change the default value. — —...
  • Page 21 Installer setting at variance with default value First Second Default code code Setting name Date Value Date Value value Range Step Unit Local shift value weather dependent Installation related setting Installation related setting Installation related setting Local shift value weather dependent 0 (OFF) 0/1/2/3/4 —...
  • Page 22: Maintenance

    This maintenance should be Dismantling of the unit, treatment of the refrigerant, of oil and of other carried out by your local Daikin technician (see installation manual). parts must be done in accordance with the applicable legislation.
  • Page 23: Appendix

    PPENDIX (for restricted power supply condition mode only) PERATING THE UNIT INFORMATION All information and settings in the manual are applicable for this application, except the information and settings 4.1. Introduction mentioned in this appendix. The heat pump system is designed to provide you a comfortable indoor climate for many years at low energy consumption.
  • Page 24: Name And Function Of Buttons And Icons

    PPENDIX (for restricted power supply condition mode only) 4.3. Name and function of buttons and icons Emergency backup heater operation always has 16. BACKUP HEATER STEP ONE OR STEP TWO priority over compressor or booster heater operation. These icons indicate that the backup heater is operating on low Emergency backup heater operation occurs because of: capacity ( ) or on high capacity ( ).
  • Page 25: Programming And Consulting The Schedule Timer

    PPENDIX (for restricted power supply condition mode only) 4.7. Programming and consulting the schedule timer All information mentioned in the manual is also applicable but additional information is required to have correct operation for the application with the restricted power supply mode activated. Programming Before you start any programming, read attentively the guidelines mentioned in...
  • Page 26 PPENDIX (for restricted power supply condition mode only) Programming space heating Programming space heating is carried out as follows: INFORMATION ■ This example describes the procedure when no program is scheduled yet. ■ Returning to previous steps in the programming procedure without saving modified settings is done by pressing the button.
  • Page 27 PPENDIX (for restricted power supply condition mode only) INFORMATION CAUTION When booster heater and domestic hot water schedule In case the disinfection function is required, the schedule timers are used, make sure they are enabled during the timer for domestic water heating and booster heating must period that space heating/cooling is disabled.
  • Page 28: Field Settings

    PPENDIX (for restricted power supply condition mode only) IELD SETTINGS ROUBLESHOOTING For applications with restricted power supply condition mode, it is not 5.1. Procedure recommended to connect the system to a benefit kWh rate power supply. Detailed description All items related to benefit kWh rate power supply should be neglected.
  • Page 32 4PW62571-1A 05.2011...

Table of Contents