Furuno FI-504 MULTI Operator's Manual page 38

Hide thumbs Also See for FI-504 MULTI:
Table of Contents

Advertisement

1
GENERAL
1.1
Indication system
1.2
Brilliance
1.3
Contrast
1.4
Display contents
1.5
Number of port
1.6
Mount method
*1) Battery voltage, date, time, water temperature, air temperature, air pressure, humidity,
wind chill temperature and dew point
*2) Fuel consumption, fuel efficiency and engine speed
2
JUNCTION BOX
2.1
Number of port
2.2
Circuit protection
3
POWER SUPPLY
3.1
Main unit
3.2
Junction box
4
ENVIRONMENTAL CONDITION
4.1
Ambient temperature
4.2
Relative humidity
4.3
Degree of protection
Main unit
Junction box
4.4 Vibration
5
COATING COLOR
5.1
Main unit
5.2
Junction box
SPECIFICATIONS OF
FI-507 MULTI XL
Segment LCD
4 steps
3 steps
Depth, Ship's speed, Wind speed/angle, Date, Time, Bearing
Environmental information
Rudder angle, Engine information
CAN bus: 2 port
Surface or flush mount
CAN bus drop: 6, CAN bus backbone: 2
Reverse, short, over current
12 VDC: 0.1 A
12 VDC: 1 A
-15°C to +55°C
95% at 40°C
IP56
IPX0
- 2 Hz-5 Hz and up to 13.2 Hz with an excursion of
±1 mm ±10% (7 m/s
Hz);
- above 13.2 Hz and up to 100 Hz with a constant
maximum acceleration of 7 m/s
N2.5
N2.5
SP - 2
*1
, Navigational information,
*2
2
maximum acceleration at 13.2
2
FI-507 MULTI XL
E7277S01A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fi-507 multi xl