d.H.W. floW SWiTCH, filTER ANd floW liMiTER
1 Remove the front panel of the case and empty the d.h.w. cir-
cuit.
2 Remove the fork D and pull up the flow switch plug E (Figure
14.3) with the help of a screwdriver.
3 To remove the body 4 with the filter from the flow switch group
rotate the flow switch plug 1 (Figure 14.5).
4 Reassemble the parts following the removing sequence in
reverse order.

14.6 flow limiter

The M296.24SM/C model is factory fitted with a 10 litres/min.
flow limiter (white).
To install the flow limiter:
1 Remove the flow switch group as explained in the section
14.5.
2 Rotate the flow switch plug 1 to separate it from the body 4
(Figure 14.5).
rotate
1
3
figure 14.5
1 Insert the flow limiter 3 as shown in Figure 14.5.
2 Reassemble the group following the above sequence in re-
verse order.