3-1. Installing Welding Generator
Movement
OR
Grounding
2
3-2. Dimensions, Weights, And Operating Angles
A
B
B
C
D
E
E
F
F
Engine End
SECTION 3 – INSTALLATION
Airflow Clearance
18 in
(460 mm)
18 in
(460 mm)
1
OR
Electrically bond generator frame to
vehicle frame by metal-to-metal
contact.
Dimensions
Height
Width
G
Depth
4 Holes
A
B
C
D
E
F
ST-800 426
G
18 in
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
3
4
GND/PE
2
install1* 3/96 – Ref. ST-800 652 / Ref. ST-800 477-A / ST-158 936-A / S-0854
31 in (787 mm)
18-3/4 in (476 mm)
46 in (1164 mm)
18 in (457 mm)
16-1/2 in (419 mm)
25
3/4 in (19 mm)
25
3-1/8 in (79 mm)
32-3/4 in (832 mm)
45-1/2 in (1156 mm)
13/32 in (10 mm) Dia.
Location
OR
1
Generator Base
2
Metal Vehicle Frame
3
Equipment Grounding
Terminal
4
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Do not exceed operating angles while
Do not exceed operating angles while
running or engine damage will occur.
i
i
d
ill
Do not move or operate unit where it could
tip
tip.
Weight
Net: 567 lb (258 kg)
Ship: 608 lb (276 kg)
OM-175 104 Page 5
25
25
25
25
angles_1 3/96