Miller Electric Big Blue 502P Owner's Manual page 37

Miller electric owner's manual welding generator big blue 502p, big blue 602p
Hide thumbs Also See for Big Blue 502P:
Table of Contents

Advertisement

B. Auxiliary Power
Trouble
No auxiliary power output; weld output
okay.
No auxiliary power or weld output.
High
output
at
auxiliary
receptacles.
Low
output
at
auxiliary
receptacles.
C. Engine
Trouble
Engine will not crank.
Engine cranks but does not start.
Engine hard to start in cold weather.
Engine suddenly stops.
Engine slowly stopped and cannot be
restarted.
Reset receptacle circuit breakers.
Disconnect equipment from auxiliary power receptacles during start-up.
Check fuses F1 and F2, and replace if open (see Section 7-7). Have Factory Authorized Service Agent
check integrated rectifier SR1, capacitor C9, and the rotor.
Reset circuit breaker CB12. Have Factory Authorized Service Agent check diode D1 (see Section 7-7).
Have Factory Authorized Service Agent check brushes and slip rings, and field excitation circuit.
power
Check engine speed, and adjust if necessary.
Have Factory Authorized Service Agent adjust auxiliary power field current resistor R3.
power
Check engine speed, and adjust if necessary.
Check fuse F1, and replace if open (see Section 7-7). Have Factory Authorized Service Agent check inte-
grated rectifier SR1 and capacitor C9.
Check battery, and replace if necessary.
Check battery connections and tighten if necessary.
Circuit breaker CB10 may be open. Turn Engine Control switch to Off position and have Factory Autho-
rized Service Agent check fuel solenoid FS1 and throttle solenoid TS1. Circuit breaker CB10 automatical-
ly resets when fault is corrected (see Section 7-7).
Check engine wiring harness plug connections.
Have Factory Authorized Service Agent check Engine Control switch S1.
Press Magnetic Shutdown switch MS1 when starting engine.
Check oil, fuel, and coolant levels. Automatic shutdown system stops engine if oil pressure or fuel level
is too low, or coolant temperature is too high (see Sections 4-7 and 7-8).
Reset circuit breaker CB13 (see Section 7-7). Have Factory Authorized Service Agent check engine-
related components and wiring.
Check battery and replace if necessary.
Have Factory Authorized Service Agent check Engine Control switch S1.
Check engine charging system according to engine manual.
Have Factory Authorized Service Agent check control relay CR2.
Air in fuel system. See engine manual.
Use starting aid switch (see Section 5-1).
Keep battery in good condition. Store battery in warm area off cold surface.
Use fuel formulated for cold weather (diesel fuel can gel in cold weather). Contact local fuel supplier for
fuel information.
Use correct grade oil for cold weather (see Section 7-2).
Check oil, fuel, and coolant levels. Automatic shutdown system stops engine if oil pressure or fuel level
is too low, or coolant temperature is too high (see Sections 4-7 and 7-8).
See engine manual.
Check fuel level.
Check engine air and fuel filters (see Sections 7-3 and 7-6).
Remedy
Remedy
OM-491 Page 33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Big blue 602p

Table of Contents