Placing Jumper Links And Connecting Input Power - Miller Electric Spectrum 1000 Owner's Manual

Air plasma cutter
Hide thumbs Also See for Spectrum 1000:
Table of Contents

Advertisement

3-10. Placing Jumper Links And Connecting Input Power

220 VOLTS
L1
L2
L3
200 VOLTS
L1
L2
L3
230 VOLTS
L1
L2
L3
1
Connect GND/PE
Conductor First
L3 (W)
L2 (V)
L1 (U)
Tools Needed:
3/8, 7/12, 1/2 in
2
380 VOLTS
L1
L2
L3
230 VOLTS
L1
L2
L3
460 VOLTS
L1
L2
L3
GND/PE
Earth Ground
L1 (U) L2 (V)
Connect GND/PE
Conductor First
4
3
415 VOLTS
L1
L2
L3
460 VOLTS
L1
L2
L3
575 VOLTS
L1
L2
L3
1
Check input voltage available at
site.
1
Jumper Link Label
Check label – only one is on unit.
2
Jumper Links
Move jumper links to match input
voltage.
L3 (W)
3
Input And Grounding
Conductors
Select size and length using Sec-
tion 3-9.
4
Line Disconnect Device
Select type and size of overcurrent
protection using Section 3-9.
Reinstall side panel.
Y Special installation may be
required where gasoline or
volatile liquids are present –
see NEC Article 511 or CEC
Section 20.
S-151 770
S-031 770-A
S-012 242-A
Ref. ST-800 718
OM-217 Page 19

Advertisement

Table of Contents
loading

This manual is also suitable for:

Spectrum 1250rSpectrum 1250

Table of Contents