Adjustment Procedures; Preparation - Icom IC-V82 Service Manual

Vhf
Hide thumbs Also See for IC-V82:
Table of Contents

Advertisement

SECTION 5

5-1 PREPARATION

REQUIRED TEST EQUIPMENTS
EQUIPMENT
Output voltage
DC power supplies*
Current capacity
Measuring range
Frequency range
RF power meter
(terminated type)
Impedance
SWR
Frequency range
Frequency counter
Frequency accuracy : ±1 ppm or better
Sensitivity
Frequency range
Audio generator
Output level
Frequency range
FM deviation meter
Measuring range
*; For UT-118 adjustment only.
CAUTION!:
BACK UP the originally programmed contents (Memory channels, Call signs, Common settings, etc.) in the transceiver
using CS-V82
When all adjustments are completed, these contents in the transceiver will be cleared.
• CONNECTION
Standard signal generator
0.1 µV to 32 mV
(–127 dBm to –17 dBm)
DO NOT transmit while
an SSG is connected to
the antenna connector.
FM
deviation meter
RF power meter
0.1–20 W/50 Ω
• ADJUSTMENT MODE DISPLAY
Adjustment item

ADJUSTMENT PROCEDURES

GRADE AND RANGE
: 5.0 V DC
8.0 V DC
: 1 A or more
: 0.1–20 W
: 100–300 MHz
: 50 Ω
: Less than 1.2 : 1
: 0.1–300 MHz
: 100 mV or better
: 300–3000 Hz
: 1–500 mV
: 30–300 MHz
: 0 to ±10 kHz
before starting adjustment.
CLONING SOFTWARE
to the antenna connector
Attenuator
20 dB / 30 dB
Frequency
counter
EQUIPMENT
Standard signal
generator (SSG)
Oscilloscope
AC millivoltmeter
External speaker
Attenuator
To [MIC] jack
To [SP] jack
IC-V82
Operating frequency
5 - 1
GRADE AND RANGE
Frequency range : 0.1–300 MHz
: 0.1 µV to 32 mV
Output level
(–127 to –17 dBm)
Frequency range : DC–20 MHz
Measuring range : 0.01–10 V
Measuring range : 10 mV to 10 V
Input impedance : 8 Ω
Capacity
: More than 0.5 W
Power attenuation : 20 or 30 dB
Capacity
: More than 5 W
AC millivoltmeter
Audio generator
• JIG
(GND)
3-conductor 3.5 (d) mm ( 1 /8") plug
(CLONE)
68 kΩ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents