Icom IC-V82 Service Manual page 15

Vhf
Hide thumbs Also See for IC-V82:
Table of Contents

Advertisement

5-2-3 RECEIVE ADJUSTMENT
ADJUSTMENT
SENSITIVITY
SQUELCH
S-METER
QUITING ADJUSTMENT
MODE
*; This output level of the standard signal generator (SSG) is indicated as SSG's terminated circuit.
ADJUSTMENT CONDITION
1 • Connect an SSG to the antenna
connector and set as;
Frequency : 136.020 MHz
Level
: 0 dBµ*
Modulation : 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
2 • Set the SSG as;
Frequency : 147.980 MHz
Level
: 0 dBµ*
Modulation : 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
3 • Set the SSG as;
Frequency : 173.980 MHz
Level
: 0 dBµ*
Modulation : 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
1 • Set the SSG as;
Frequency : 145.020 MHz
Level
: −19 dBµ*
Modulation : 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
1 • Set the SSG as;
Frequency : 145.020 MHz
Level
: −6 dBµ*
Modulation : 1 kHz
Deviation
: ± 3.5 kHz
• Receiving
1 • Turn power OFF.
2 • While pushing [MONI] and [D•CLR] keys, turn power ON.
OPERATION
• Push [D•CLR] key.
• Push [D•CLR] key.
• Push [D•CLR] key.
• Close the squelch once, then set the
squelch level at the point where the
audio signals just appears.
• Push [D•CLR] key.
5 - 3

Hide quick links:

Advertisement

Table of Contents
loading