5-8. Installing PD Continuous Wire Guides

2
1
3
4
.
PD Continuous Wire Guides:
Should be
used
with
.068/.072 in (1.8 mm) and
smaller diameter wire for opti-
mal performance.
Should be used with PD
drive rolls and cannot be used
with non-PD (old-style) drive
rolls.
.
70 series wire guides are not
compatible with 75 series wire
feeders.
1
Pressure Door Assembly
2
PD Inlet Guide
3
PD Wire Guide (Hard Wire)
4
PD Wire Guide (Two Pieces
interlocked for Aluminum
Wire)
Installing PD continuous wire
guides with PD drive rolls.
.
Drive rolls are identified by the
initials PD and a part number
on the drive roll.
Open pressure door assembly.
Lift up drive roll swing arms.
Remove PD inlet guide.
Insert wire guide gun end (indi-
cated with arrow) into block near
brass power pin gun connector.
Install PD inlet guide.
.
Do not tighten set screw to se-
cure inlet guide.
.
Set screw may be used to se-
cure PD inlet guide replace-
ments such as wire straighten-
ers or conduit adapters.
Ref. 804 188-B
OM-228 322 Page 15