Program 11 −− .045 Metal Core −− Recommended Gases: Argon/CO
IPM
Trim
100
0
145
10
190
20
235
30
280
40
325
50
370
60
415
70
460
80
505
90
550
100
Program 12 −− .052 Metal Core −− Recommended Gases: Argon/CO
IPM
Trim
60
0
99
10
138
20
177
30
216
40
255
50
294
60
333
70
372
80
411
90
450
100
Gas: Argon/CO
mixes up to 20% CO
2
Peak Amp
Background Amp
310
45
330
61
354
70
365
78
370
89
376
100
381
111
385
122
390
138
395
155
400
175
Gas: Argon/CO
mixes up to 20% CO
2
Peak Amp
Background Amp
360
36
365
70
370
94
374
116
379
133
384
147
387
160
390
174
393
186
396
199
400
210
2
2
Freq.
Pulse Width
50
2.30
65
2.45
90
2.55
110
2.65
130
2.75
150
2.85
165
3.00
180
3.15
190
3.25
200
3.35
205
3.45
2
2
Freq.
Pulse Width
40
2.00
50
2.10
73
2.20
94
2.35
112
2.50
129
2.65
144
2.85
159
3.00
174
3.15
189
3.35
204
3.50
Starting Amps
529
529
529
529
529
529
529
529
529
529
529
Starting Amps
529
529
529
529
529
529
529
529
529
529
529
OM-188 304 Page 31