Weld Output Receptacles And Selecting Cable Sizes - Miller Electric 230Volt Owner's Manual

Arc welding power source with built-in synergic control 230/460 and 460/575 volt models
Table of Contents

Advertisement

4-2. Weld Output Receptacles And Selecting Cable Sizes

!
ARC WELDING can cause Electromagnetic Interference.
To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor.
Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed
and grounded according to this manual. If interference still occurs, the user must take extra measures such as moving
the welding machine, using shielded cables, using line filters, or shielding the work area.
Weld Output
Terminals
!
Turn off power before
connecting to weld out-
put terminals.
!
Do not use worn, dam-
aged, undersized, or
poorly spliced cables.
+
Output Receptacles
Output Receptacles
This chart is a general guideline and may not suit all applications. If cable overheats use next size larger cable.
*
**Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere.
2
( ) = mm
for metric use
***For distances longer than those shown in this guide, call a factory applications representative at 920-735-4505.
OM-188 304 Page 14
Weld Cable Size** and Total Cable (Copper) Length in Weld Circuit
100 ft (30 m) or Less
100
4 (20)
4 (20)
150
3 (30)
3 (30)
200
3 (30)
2 (35)
250
2 (35)
1 (50)
300
1 (50)
1/0 (60)
350
1/0 (60)
2/0 (70)
400
1/0 (60)
2/0 (70)
500
2/0 (70)
3/0 (95)
600
3/0 (95)
4/0 (120)
Not Exceeding***
150 ft
200 ft
250 ft
(45 m)
(60 m)
(70 m)
4 (20)
3 (30)
2 (35)
2 (35)
1 (50)
1/0 (60)
1 (50)
1/0 (60)
2/0 (70)
1/0 (60)
2/0 (70)
3/0 (95)
2/0 (70)
3/0 (95)
4/0 (120)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
3/0 (95)
4/0 (120)
(2x70)
2 ea. 2/0
2 ea. 3/0
4/0 (120)
(2x70)
(2x95)
2 ea. 2/0
2 ea. 3/0
2 ea. 4/0
(2x70)
(2x95)
(2x120)
300 ft
350 ft
400 ft
(90 m)
(105 m)
(120 m)
1 (50)
1/0 (60)
1/0 (60)
2/0 (70)
3/0 (95)
3/0 (95)
3/0 (95)
4/0 (120) 4/0 (120)
2 ea. 2/0
2 ea. 2/0
4/0 (120)
(2x70)
(2x70)
2 ea. 2/0
2 ea. 3/0
2 ea. 3/0
(2x70)
(2x95)
(2x95)
2 ea. 3/0
2 ea. 3/0
2 ea. 4/0
(2x95)
(2x95)
(2x120)
2 ea. 3/0
2 ea. 4/0
2 ea. 4/0
(2x95)
(2x120)
(2x120)
2 ea. 4/0
3 ea. 3/0
3 ea. 3/0
(2x120)
(3x95)
(3x95)
3 ea. 3/0
3 ea. 4/0
3 ea. 4/0
(3x95)
(3x120)
(3x120)