setup screen

ptZ setup

Configure the connection settings to the external pan/tilt receiver so that you can control
the PTZ operations via the receiver connected to the RS-485 port of the camera.
1. Select the <audio & video (
from Setup menu.
2. Click <ptZ setup>.
3. Specify the serial port.
You can set the RS-485 communication
mode for pan/tilt-compliant receiver that
is connected to the network camera.
• Protocol : From SAMSUNG-T/
SAMSUNG-E / PELCO-D/PELCO-P
/ SUNGJIN, select the same protocol
as that of the receiver.
• Camera ID : Provide a camera ID.
• Baudrate : Transfer rate for RS-485 communications
• Data bit : Specify the data bit.
• Parity bit : Specify the parity bit.
• Stop bit : Specify the stop bit.
4. When done, click [apply (
All these operations above mentioned will be enabled only if the network camera is properly
`
M
connected to the pan/tilt-compliant receiver. And the serial port for the pan/tilt operations should
be properly specified.
The baud rate may not be controlled depending on the product specifications.
`
J
5. Click [Direction adjustment (
• [change direction to (
lens.
• [moving speed control (
moving speed becomes.
50_ setup screen
)> tab
)].
)].
)/(
)/(
)/(
)] : Change the direction of camera
)] : The bigger the number is, the faster the