7-2. Operation Data

<Cooling>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
27/19
35/24
137SKV-E
167SKV-E
<Heating>
Tempeature
Model name
condition(°C)
RAS-
Indoor
Outdoor
20/15
7/6
137SKV-E
167SKV-E
NOTES :
1. Measure surface temperature of heat exchanger pipe around center of heat exchanger path U bent.
(Thermistor themometer)
2. Connecting piping condition : 5 m
Heat exchanger
Standard
pipe temp.
pressure
P (MPa)
T1 (°C)
0.8 to 1.0
11 to 13
0.7 to 0.9
10 to 12
Heat exchanger
Standard
pressure
pipe temp.
P (MPa)
T1 (°C)
2.7 to 2.9
43 to 45
2.5 to 2.7
39 to 41
– 22 –
FILE NO. SVM-08011
Indoor
fan mode
T2 (°C)
39 to 41
High
47 to 49
High
Indoor
fan mode
T2 (°C)
0 to 2
High
0 to 2
High
Outdoor
Compressor
fan mode
revolution
(rps)
High
77
High
89
Outdoor
Compressor
fan mode
revolution
(rps)
High
80
High
89