R
C. Equivalent Feet of Pipe
The table below can help you calculate the equivalent feet
of pipe which is a method used to determine pellet vent size.
Figure 12.1
 ft.
2 ft.
Figure 12.1
D. Pipe Selection Chart
The chart will help you in determing proper vent-
ing size according to the equivalent feet of pipe
calcuated above and the altitude above sea level
of this installation. See Figure 11.2.
Locate the calculated equivalent feet of pipe on
the vertical left side of the chart. Move to the
right horizontally on the chart until you reach
your altitude above sea level.
If you fall below the diagonal line,  or 4 inch (76
to 102mm) pipe may be used. If it is anywhere
above the diagonal line, a 4 inch (102mm) diam-
eter pipe is required.
The chart reveals that a 90° elbow is 5 times as
restrictive to the flow of exhaust gases under
positive pressure as 1 foot of horizontal pipe, and
a foot of horizontal pipe is twice as restrictive as
a foot of vertical pipe.
Page 12
Example of 3 Elbow-Rear Vent Termination Calculaton
2 ft.
2 ft.
Improper installation, adjustment, alteration, service or
maintenance can cause injury or property damage. Refer
to the owner's information manual provided with this appli-
ance. For assistance or additional information consult a
qualified installer, service agency or your dealer.
Pellet Venting
# of
Feet of
Component
Elbows
Pipe
o
90
Elbow or Tee
3
o
45
Elbow
Horizontal Pipe
7
Vertical Pipe
2
Note: This is a generic example and is not
intended to represent any specific fuel type.
30
Example 1
20
Equivalent Pipe
Length In Feet
Example 2
10
3 in. or 4 in. (76mm or 102mm) Diameter Pipe
0
1
Figure 12.2
Example 1: If the equivalent length of pipe is 2 feet with altitude of
8,000 feet you must use 4 inch (102mm) diameter type "L" or "PL"
vent.
Example 2: If the equivalent length of pipe is 12 feet with altitude of
6,000 feet you may use  or 4 inch (76 to 102mm) diameter type "L"
or "PL" vent
7021-130
Castile-B FS Pellet Stove
WARNING
Multipled
Equivalent
By
Feet
X
5
X
3
X
1
X
0.5
Total Equivalent Feet
4 in. (102mm) Diameter Pipe Only
2
3
4
5
6
7
ALTITUDE IN THOUSANDS OF FEET
September 24, 2009
Components
Equivalent Feet
15
7
1
23
8
9
10

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Castile-cwl-bCastile-csb-bCastile-pmh-b

Table of Contents