Electrical connection

Before connecting the appliance
read the "Warning and Safety
Instructions" and the "Electrical data"
sections.
^ Plug the 2 connectors on the canopy
into the corresponding receptacles
left and right of the motor assembly.
Insert the 4 prong connector into the
rear and the 3 prong connector into
the front receptacle left of the motor
assembly.
Insert the 6 prong connector into the
receptacle right of the motor
assembly.
^ Secure the cords with the ties, as
shown above.
^ Plug in the power cord.
Air extraction exhaust
connection
^ Connect the ductwork to the exhaust
connection using whatever means
are appropriate for the type of
ductwork being installed (hose
clamp, duct tape, etc.)
^ Direct the duct through the back wall
or the ceiling.
^ See "Air extraction" for further details.