Advertisement

Operating and Installation instructions
Rangehood
DA 3160
DA 3190
en - AU, NZ
To avoid the risk of accidents
or damage to the appliance,
it is essential to read these
instructions before it is installed
and used for the first time.
M.-Nr. 07 777 880

Advertisement

Table of Contents
loading

Summary of Contents for Miele DA 3160

  • Page 1 Operating and Installation instructions Rangehood DA 3160 DA 3190 en - AU, NZ To avoid the risk of accidents or damage to the appliance, it is essential to read these instructions before it is installed and used for the first time.
  • Page 2: Table Of Contents

    Contents Caring for the environment ......... . 3 Warning and Safety instructions .
  • Page 3: Caring For The Environment

    Caring for the environment Disposal of the packing Disposal of your old appliance material or machine The transport and protective packing Electrical and electronic appliances / has been selected from materials which machines often contain materials are environmentally friendly for disposal which, if handled or disposed of and can normally be recycled.
  • Page 4: Warning And Safety Instructions

    Any other usage is not supported by requirements. Inappropriate use the manufacturer and could be can, however, lead to personal injury dangerous. Miele cannot be held liable and damage to property. for damage resulting from incorrect or improper use or operation of the To avoid the risk of accidents and appliance.
  • Page 5: Technical Safety

    Installation, maintenance and rangehood for visible signs of damage. repairs may only be carried out by a Under no circumstances should you Miele authorised person in accordance use a damaged appliance. It could be with current national and local safety dangerous.
  • Page 6 These models may only be combined with a Miele external motor. This rangehood must not be installed and operated in mobile installations (e.g. on a ship).
  • Page 7 Warning and Safety instructions In order to ensure safe operation, and to prevent gases given off by the heating appliances from being drawn back into the room when the rangehood and the heater are in operation simultaneously, an underpressure of 0.04 mbar (4 pa) is the maximum permissible in the room.
  • Page 8: Correct Use

    Warning and Safety instructions Correct use Do not use the rangehood without the filters in place. This way you will Never use an open flame beneath avoid the risk of grease and dirt getting the rangehood. To avoid the danger of into the appliance and hindering its fire, do not flambé...
  • Page 9: Correct Installation

    Safety regulations prohibit the fitting of a rangehood over solid fuel stoves. All ducting, pipework and fittings must be of non-flammable material. These can be obtained from the Miele Spare Parts department or from builders' merchants. The appliance must not be connected to a chimney or vent flue which is in use.
  • Page 10: Guide To The Appliance

    Guide to the appliance...
  • Page 11 The front of the deflector plate can be fitted with a lightshield to match your kitchen furniture. The DA 3160 and DA 3190 can be fitted with a DFB 61 or DFB 91 lightshield, available as an optional accessory.
  • Page 12: Description Of The Functions

    Chartered Agent or from socket in the motor unit. Miele or via the internet at www.miele-shop.com (check availability). Having a non-return flap fitted in the See back cover for contact details and ducting ensures that air, once ducted "Technical Data"...
  • Page 13: Operation

    Operation The rangehood is operated by pulling For short periods of cooking food with out and pushing in the deflector plate. intensive vapours and a strong aroma, e.g. when searing meat, you may wish to select the Intensive Setting "IV". To switch the fan on Pull the deflector plate right out to ^ Pull out the deflector plate.
  • Page 14 Operation Automatic switch-off of the Intensive The indicator lamps for fan power levels setting I and IV will flash if the automatic switch-off of the Intensive setting is not You can set the Intensive setting so that activated. it only runs for 10 minutes before reverting automatically to level III.
  • Page 15: Cleaning And Care

    Wait several minutes after switching off before beginning cleaning. Important for appliances with stainless steel housing A range of Miele branded cleaning and (This infomation does not apply to the conditioning agents are available to order controls) through your Miele Chartered Agent, from...
  • Page 16: Grease Filter

    Cleaning and care Grease filter Controls The re-usable metal grease filter in the The controls may suffer appliance removes solid particles from discolouration or damage if soiling is the kitchen vapours (grease, dust, etc) left on them for too long. Remove preventing soiling of the rangehood.
  • Page 17 ^ Do not wash at more than 65 °C. If a upwards and push it in together with Miele dishwasher is being used, the deflector plate. It will slide onto select the Sensor wash programme.
  • Page 18: Fitting And Replacing The Charcoal Filter

    It is fitted in the canopy above the grease filter. Replacement charcoal filters can be obtained from your Chartered Agent, from Miele or via the internet at www.miele-shop.com. See back cover for contact details, and "Technical data" for type and reference number.
  • Page 19: Changing A Halogen Lamp

    Cleaning and care Changing a halogen lamp ^ Pull out the deflector plate, and remove the grease filter as described earlier. ^ Switch off the fan and the lighting. Exercise caution when changing halogen lamps. They get very hot during use, and remain hot for some time after being switched off.
  • Page 20: Appliance Dimensions

    Appliance dimensions DA 3190* DA 3160 1) In extraction mode: when measuring for the height of the wall housing unit and the cut-out, account must be taken of any accessories fitted, e.g. a condensate barrier. 2) Recirculation mode requires installation kit DUU 151.
  • Page 21 – 650 mm above an open grill or deep fat fryer, – 650 mm above gas cooktops If this rangehood is installed above a Miele Wok CS 1028 CombiSet appliance, a minimum safety distance of 760 mm must be maintained between the burner and the lower edge of the rangehood.
  • Page 22: Installation

    Installation Installation accessories...
  • Page 23 Installation a 1 exhaust connection for exhaust ducting C 150 mm. b 1 non-return flap 8 screws 3.5 x 16 mm for fitting into the exhaust socket on for securing the rangehood into the wall the motor unit (only for air extraction unit.
  • Page 24 Installation...
  • Page 25: Positioning The Appliance In The Wall Housing Unit

    Installation Positioning the appliance in the wall housing unit To position the appliance correctly, cut the spacer strip to required depth T, and then attach it to the back of the appliance. T= Depth of carcase K minus depth of ^ Screw the spacer strip to the bottom appliance G of the sides of the housing, flush with...
  • Page 26 Installation ^ Place the appliance on its back. Do not remove the protective film between the deflector plate and the casing until the rangehood has been placed in the housing unit. ^ Screw the brackets onto the right and left inside walls of the housing unit as shown.
  • Page 27 Installation Note for dismantling the rangehood: Undoing the screws on the left and right inside the housing releases the brackets, allowing the appliance to ^ When fitting a DA 3190 into a 60 cm be removed from the unit. housing unit, unscrew the brackets on the deflector plate whilst it is ^ Push the rangehood back against the pulled out.
  • Page 28 Installation ^ Secure the spacer strip to the back of the appliance from behind using 4 plastic rivets as shown. ^ Loosen the screws of the fixing brackets on the top of the appliance. ^ Push the brackets flush to the wall or the cabinet back wall.
  • Page 29: Attaching The Lightshield

    Installation Attaching the lightshield Aligning the deflector plate ^ Attach the lightshield (if using). A DML 300 installation kit, available as an optional accessory, is required for this. This installation kit is supplied with a ^ The position of the deflector plate DFB lightshield.
  • Page 30: Replacing The Grease Filter

    Installation Replacing the grease filter Set up for extraction mode ^ Remove the protective strip around the edge of the grease filter. ^ If the on-site ventilation system does Replace the grease filter. not have a non-return flap, then the non-return flap supplied with the ^ To do this, pull the deflector plate out.
  • Page 31: Set Up For Recirculation Mode

    For this, a conversion kit DUU 151, available from your Miele Chartered Agent, or Miele is required. ^ Fit the conversion kit as described in the installation instructions supplied with the kit.
  • Page 32: Connection For Air Extraction

    Connection for air extraction – The exhaust ducting should not be Important: To avoid the danger of kinked or compressed. toxic fumes, please observe the – Ensure that all connections are Warning and Safety instructions. strong and airtight. This is especially crucial when using the rangehood at the same time as –...
  • Page 33: Condensate Trap

    Connection for air extraction Condensate trap (optional accessory) For installations in areas where the exhaust ducting is exposed to cold temperatures, we recommend insulating the exhaust ducting and installing a condensate trap to collect and evaporate any condensate which may occur. Condensate traps are available for C 125 mm or C 150 mm ducting.
  • Page 34: Silencer

    Connection for air extraction Silencer (DASD 150, optional accessory) ...with air extraction: The silencer not only reduces noise from the fan, but also sounds from outside (e.g. traffic noise). To achieve even further reductions in For this reason, the silencer must be noise levels, a special silencer can be positioned as close as possible to where fitted in the ducting system.
  • Page 35: Electrical Connection

    Electrical connection If the switch is not accessible after All electrical work should be installation, an additional means of undertaken by a suitably qualified disconnection must be provided for all and competent person in strict poles. accordance with current national For extra safety, it is advisable to install and local safety regulations.
  • Page 36: Operation With Dsm 400 Control Module

    Operation with DSM 400 control module The Miele DSM 400 control module can If the control module is be used to combine the rangehood with disconnected in order to operate the other components. rangehood without the window It enables the following: contact switch (e.g.
  • Page 37: Connection To A Light Switch

    Operation with DSM 400 control module Connection to a light switch The control module can be used to switch on the rangehood lighting via a light switch in the house. Installation The control module must be installed above the rangehood housing. The control module is supplied with its own detailed operating and installation instructions.
  • Page 38: After Sales Service

    – your Miele Chartered Agent or – Miele You will find the telephone number and address of Miele on the back cover of the manual. Please quote the model and serial number when contacting Miele. These...
  • Page 39: Technical Data

    Weight DA 3160....12,5 kg DA 3190....14,5 kg...
  • Page 40 Alteration rights reserved / 4511 M.-Nr. 07 777 880 / 04...

This manual is also suitable for:

Da 3190