Installation - extraction ducting
To calculate the effective duct
length
Friction against the inner walls of the
vent ducting will slow down the
expelled air as it passes through the
ducting. An elbow, bend, non-return
flap or wall vent creates more friction
than a straight duct. The friction
created by each of these is expressed
as an additional duct length factor.
The additional duct length factors are
calculated by comparing the friction
created by, for example, an elbow to
that created by 1 metre of straight
plastic piping (see Table 1).
The additional duct length factor for
each item needs to be added together
to ascertain the effective duct length
which will be needed for the venting
system. The effective duct length is a
means of calculating the friction
created by the venting system as a
whole.
A larger internal duct diameter also
helps reduce friction. If the effective
duct length is more than 20 m, the
duct diameter should be increased
(see Table II).

To calculate the effective duct length

1. First measure the distance requiring
straight ducting. Multiply this amount
by the corresponding additional
length factor in Table I.
2. Establish the number of angles,
bends etc., and add their additional
length factors together with the help
of Table I.
38
3. Add all the additional length factors
to give the effective duct length.
4. Refer to Table II for the appropriate
duct diameter required.
Table I
Component
Flexible ducting*
1 m laid straight
45° angle
(Bend radius = 0.25 m)
90° angle
(Bend radius = 0.25 m)
Flexible aluminium
ducting*/plastic piping
1 m laid straight, or 1 m
straight pipe
45° angle
(Bend radius = 0.25 m)
90° angle
(Bend radius = 0.25 m)
Wall vent kit* or window vent
kit*
with louvred grill
with non-return flap (hinged
flap)
Non-return flap* integrated into
the vent ducting
Flat ducting (for washer-dryer
stack)*
Venting connection to the
left/right
* accessory available to order
Table II
Maximum effective
duct length allowable
20 m
40 m
80 m
Additional
duct
length
factor
1.8 m
1.5 m
2.5 m
1.0 m
0.6 m
0.8 m
3.8 m
1.5 m
14.3 m
11.0 m
1.0 m
Internal duct
diameter required
100 mm
125 mm
150 mm