Installing And Removing A Passive Cpu Heatsink - Supero SuperServer 5028R-WR User Manual

Table of Contents

Advertisement

S
S
UPER
ERVER 5028R-WR User's Manual
7. With the CPU in the socket, in-
spect the four corners of the CPU
to make sure that they are flush
with the socket.
8. Close the load plate. Use your
thumb to gently push the lever
labeled 'Close 1st' then the lever
labeled 'Open 1st' down until they
lock.
9. Repeat steps to install to the
remaining CPU socket.
Push down and lock the
level labeled 'Close 1st'.

Installing and Removing a Passive CPU Heatsink

1. Do not apply any thermal grease to the heatsink or the CPU die; the required
amount has already been applied.
2. Place the heatsink on top of the CPU so that the four mounting holes are
aligned with those on the serverboard and the heatsink bracket underneath.
3. Screw in two diagonal screws (i.e., the #1 and the #2 screws) until just snug
(to avoid possible damage to the CPU, do not over-tighten the screws.)
4. Add the two remaining screws then fully tighten all four screws.
Gently close
the load plate.
Lever Lock
5-6
Push down
and lock the
lever labeled
'Open 1st'.