TO FILL AND TURN ON THE WATER HEATER
The power supply to the water heater must not be switched on until the water heater is filled with
water and a satisfactory megger reading is obtained.
Open all of the hot water taps in the house (don‟t forget the shower).
Open the cold water isolation valve fully to the water heater.
Air will be forced out of the taps.
Close each tap as water flows freely from it.
Check the pipe work for leaks.
Switch on the electrical supply at the isolating switches to the water heater.
Set the timer if one is installed.
The heat pump may take up to 30 seconds to commence operating when the power supply is switched on.
The heat pump will only operate when the water in the storage tank requires heating, the heat pump
compressor is cool and power is available at the water heater.
When the heat pump is operating, the system may switch to the booster heating unit if it detects that the
ambient air temperature is below the minimum operating temperature of 5°C. It may also switch back to heat
pump operation from the booster heating unit if it detects the ambient air temperature has moved back to
within the heat pump‟s operating temperature range.
If the ambient air temperature is below 0°C (solid red LED), the heat pump will not operate and the booster
heating unit will operate instead.
Note: The heat pump may not turn on after having just completed a heating cycle and more hot water is
drawn from the water heater, or if power was switched off whilst the heat pump was operating. The heat
pump will wait at least 5 minutes, and until the compressor has cooled down and the conditions for start up
are favourable, in order to protect the compressor from damage. This may take up to 20 minutes from the
last heating cycle.
It is important to wait for five minutes after the heat pump has activated to ensure it continues to operate and
is functioning correctly.
Explain to the householder or a responsible officer the functions and operation of the heat pump water
heater. Upon completion of the installation and commissioning of the water heating system, leave this guide
with the householder or a responsible officer.
TO TURN OFF THE WATER HEATER
If it is necessary to turn off the water heater on completion of the installation, such as on a building site or
where the premises are vacant, then:
Switch off the electrical supply at the isolating switches to the water heater.
Close the cold water isolation valve at the inlet to the water heater.
Notes
The freeze protection system will be rendered inoperable if electrical power is not available at the water
heater.
Damage caused by freezing due to the unavailability of power at the water heater is not covered by the
Rheem warranty (refer to
If the power has been switched off to the water heater and there is a risk of freezing, then it is necessary
to drain the water heater (refer to

COMMISSIONING

"Terms of the Rheem Warranty"
"Draining The Water Heater"