4 Replacement Procedures
Installing the Fingerprint sensor board
To install the fingerprint sensor board, follow the steps below and refer to Figure 4-13.
1. Connect the fingerprint sensor cable to the connector on the fingerprint sensor
board.
2. Stick a new double-sided tape in place and install the fingerprint sensor board
while inserting it under the guides.
CAUTION: Do not reuse the removed double-sided tape.
3. Place the fingerprint sensor board cover while sliding it under the guides and
inserting the slit into the guide.
4-22
[CONFIDENTIAL]
4.9 Fingerprint sensor board
PORTÉGÉ R300 Maintenance Manual (960-591)