USB/ MOUSE
10
11

3.1.3 Alarm input port

8chanel alarm input, the mode of alarm input is no restriction (possible is normal open also normal close);
the GND alarm detector connect to COM under parallel connection (the power of alarm detector supply by
external power supply;
the ground terminal of alarm detector join-up in parallel with DVR;
the NC of alarm detector connect with the input end (alarm) of DVR;
when you want to reset the remote alarm of triggered , the +12V power supply of alarm detector supply by DVR,
for example, smoke detector.
When you select the external power supply, please share the GND with DVR;
Alarm input circuit:
Alarm inlet connection:
3.1.4
Alarm
output port
4 way switching
value alarm output,
selectable in normally open contact, also selectable in normally closed contact, the external alarm
device should be need Vcc;
ON/OFF
DC-12V
First USB for backup or upgrade system of DVR;Second
USB for mouse
Power supply switcher
Power adapter port
ALARM IN:4CH alarm input port
RS-485:A, B
ALARM OUT: N1 N2 for alarm output port, every channel
connect C and O;
port is for GND;