Disassembly
To avoid risk of electrical shock, personal injury, or death, disconnect electrical power source to unit, unless test
procedures require power to be connected. Discharge capacitor through a resistor before attempting to service.
Ensure all ground wires are connected before certifying unit as repaired and/or operational.
Blower Removal
Remove the four screws holding the blower
assembly to dishwasher.
Pull blower assembly out towards you slowly
as shown above. Disconnected blower motor
connection as shown below.
34
!
WARNING
The blower can be released from mount by
using a small screwdriver to release tabs,
see inset in photo below. Release tabs and
slide blower assembly and pull out of mount.
Reverse previous procedures to install the
blower.
Release
tab
©2012 Viking Preferred Service