Installer's Setup - Trane 7CONT624AS42DA User's Manual And Installation Instructions

Touchscreen comfort control
Table of Contents

Advertisement

Installer's Setup

Installer Settings allow the user to configure the equipment settings and customize how the control operates. To
access Installer Settings press the Menu button, then press Next until Service is displayed. Now press Select and hold
for 5 seconds until "Installer Settings" is displayed. Press Select again to enter Installer Settings menu. The default
setting will be shown in brackets. After each selection press Done to save changes.
Setting
Outdoor Unit Type
Outdoor Unit Stages
Compressor Type
Indoor Unit Type
Indoor Heat Stages
Indoor Blower Type
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
Setting
Compressor Stage 1 MRT
Compressor Stage 2 MRT
Compressor MOT
Indoor Heat Stage 1 MRT
Indoor Heat Stage 2 MRT
Indoor Heat MOT
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
Setting
Sensor Calibration
Remote Sensor
Remote Sensor Calibration *-7 - +7 Degrees [0]
Outdoor Sensor
Outdoor Sensor Calibration *-7 - +7 Degrees [0]
RH Calibration
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
Setting
Aux Relay
Ventilation On Timer
Once all selections have been made, press the Done button to exit and return to Menu. Press Next to navigate to the next setting.
30
Installer's Guide
Range
None, [AC], HP
[1], 2
1 Comp - 2 Stage,
[2 Comp - 2 Stage]
[Gas/Oil], Electric, Hydronic
[1], 2, 3
[Non - Variable], Variable
Range
[3] - 9 Minutes
[3] - 9 Minutes
[5] - 9 minutes
[3] - 9 Minutes
[3] - 9 Minutes
[5] - 9 minutes
Range
*-7 - +7 Degrees [0]
[None], Replace Indoor, Average
[None], Outdoor
*-7% - +7% [0]
Range
[None], Ventilation, Dehumidifier
[Off], 1 - 60 Minutes
Equipment Type
Select the type of outdoor unit installed
Select the number of outdoor unit stages
Select the compressor type for multi-stage outdoor units
Select the type of indoor unit installed
Select the number of indoor heat stages
Select the indoor blower type (Constant Torque motors are considered
non-variable speed)
Equipment Settings
Select the minimum runtime (MRT) of stage 1 compressor operation
Select the minimum runtime (MRT) of stage 2 compressor operation
Select the minimum offtime (MOT) for compressor operation
Select the minimum runtime (MRT) of stage 1 indoor heat
Select the minimum runtime (MRT) of stage 2 indoor heat
Select the minimum offtime (MOT) for indoor heat operation
Sensor Settings
Calibrate the indoor temperature sensor (do not attempt to calibrate the
indoor temperature within the 1st hour upon power-up)
Select whether a remote indoor temperature sensor has been connected,
and if a remote sensor has been connected, indicate whether to use the
remote sensor to replace the onboard temperature sensor or average the
two.
Calibrate the remote temperature sensor
Select whether an outdoor temperature sensor has been connected
Calibrate the outdoor temperature sensor
Calibrate the RH sensor
Accessories
Select what accessory the Aux Relay is controlling
Select the minimum runtime per hour of the ventilation equipment
Description
Description
Description
Description