Operation

The model TCONT624AS42DAA Comfort Control provides typical operation of a forced air heating and cooling HVAC system. The TCONT624
comfort control also features a Z-Wave™ module for remote control.
Normally, the Comfort Control displays the Home Screen as shown above.
Item
Clock Display
Dynamic Labels and Func-
tion Control Buttons
Setpoint Display and Set-
point Up/Down Buttons
Temperature Display
Menu Button
System Mode Button
Fan Mode Button
Schedule Mode Button
:
PM
Menu
Description
The current time is displayed in the upper left corner
of the main screen. The time will blink when the clock
has not been set.
The buttons are defined by the dynamic labels in each
button. As you navigate through menus, the labels for
the buttons will change.
The current heat or cool setpoint is displayed. These
setpoints may be set at https://emonitor.us
or by pressing the Set- point Up/Down buttons.
Pressing the setpoint button changes the setpoint
screen. The current mode is display at the top of the
screen. Adjust the setpoint by pressing the up or
down arrows. To change setpoint mode, press the
MODE button.
The Comfort Control displays the current temperature
as sensed by the internal temperature sensor.
Button used to access other Comfort Control menus
Button used to change the system mode
Button used to change the fan mode:
Button used to change the schedule mode:
User Guide
F
Cooling
Hold
Cool
Auto
Sched
Mode
Fan
See TIME/DATE for more information.
The clock will be updated by the eMonitor.
The setpoints will push each other if they are adjusted
to within the minimum heat/cool separation setting.
This is normally 3 degrees.
The internal temperature sensor can be adjusted as
necessary.
Other Comfort Control menus can be accessed by
pressing the MENU button.
Off: System off
Heating: Heating only
Cooling: Cooling only
Auto: Heating/Cooling as necessary
EM Heat: Indoor Heat only
Auto: Fan on when cooling/heating is necessary
On: Fan constantly on
Circ: Fan on for a user-selected number of minutes
per hour.
Hold: System maintains the current temperature set-
points. Schedules are disregarded.
Run: Run the system schedule
Energy Saving Mode (ESM): Temperature setpoints in
ESM Setpoints are maintained.
Notes