OTHER FUNCTIONS

I Power save

The power save function reduces the current drain to con-
serve battery power.
The power save duty cycle, the ratio of receive circuit on to
receive circuit off during standby, can be set to automatic
, 1 : 1
fault)
(150 msec. : 150msec.)
: 8
(150 msec. : 1200msec.)
mode.
(p. 88)
MENU screen
(Push [MENU/LOCK]) (Rotate [DIAL]
• "AUTO" selects "1:1" duty ratio when receiving no signal for 5 sec.,
then "1:4" 60 sec. after that. The ratio becomes "1:8" when no signal
is received for another 60 sec.
No signal
5 sec.
Circuit ON
Circuit OFF
114
, 1 : 4
(150 msec. : 600msec.)
or OFF with "POWER SAVE" in set
SET MODE
POWER SAVE
, then push [ï](5)
150 msec.
600 msec.
1200 msec.
150 msec.
60 sec.
60 sec.

I Auto power OFF

The transceiver can be set to automatically turn OFF after a
specified period with a beep when no switch is pushed.
120 min., 90 min., 60 min., 30 min. and OFF can be speci-
fied. The specified period is retained even when the trans-
(de-
ceiver is turned OFF by the auto power-off function. To cancel
, 1
the function, select "OFF" in the auto power-off item in set
mode.
This can be selected with "AP OFF" in set mode.
.)
MENU screen
(Push [MENU/LOCK]) (Rotate [DIAL]

I Auto power ON

The transceiver can be set to automatically turn ON after a
specified period. The timer can be selected within 30 min. to
24 hrs. in 30 min. steps.
This can be selected with "AP ON" in set mode.
MENU screen
(Push [MENU/LOCK]) (Rotate [DIAL]
When operating with battery pack or case and the battery
is exhausted, auto power-on does not function.
A slight current still flows in the circuits during standby con-
dition of the auto power-on function.
SET MODE
AP OFF
, then push [ï](5)
(p. 89)
SET MODE
AP ON
, then push [ï](5)
(p. 88)
.)
.)