Operation Details
* Lo -- :
* SLo :
* RLo :
Random Low Speed
Fan Speed
Time
Fan Motor
10) Airflow Direction Control
a) Vertical Airflow Direction
Cooling and Soft Dry Mode.
Airflow Direction Auto-Control
36°
140.5°
Closing
position
• The louver swings up and down as shown above.
• The louver does not swing when the Indoor Fan
stops during operation.
b) Vertical Airflow Direction
Heating Mode
Airflow Direction Auto-Control
61°
140.5°
Closing
position
• When the intake air temp. reaches 38°C, the louver
is changed from upper to lower limit. When the
intake air temp falls to 35°C, the louver is changed
from lower to upper limit.
C)Horizontal Airflow Direction
• The left and right airflow direction louvers can be adjusted manually.
Indoor Fan rotates at 6 seconds ON and 4 seconds OFF
Indoor Fan rotates at 4 second intervals at Low speed.
Random Low Speed.
Lo, RLo - , RLo -- , Fan Speed is operates randomly.
Lo
10"
ON
Horizontal
Upper limit
Swing up
and down
Lower limit for Cooling
and soft Dry Mode
Horizontal
Upper limit
Lower limit
for Heating Mode / 61°
RLo -
4.5"
0.5"
4.5"
0.5"
ON
OFF
ON
OFF
Airflow Direction Manual-Control
140.5°
Closing
position
• The louver can be selected between 0°– 36° (as
shown above) when pressing Manual Airflow
Direction Selection Button.
Airflow Direction Manual-Control
140.5°
Closing
position
• The louver can be selected between 0° – 61° (as
shown above) when pressing Manual airflow Direc-
tion Selection Button.
– 28 –
RLo --
4"
1"
4"
1"
ON
OFF
ON
OFF
Horizontal
Upper limit / 0°
18°
27°
Lower limit for
Cooling and Soft Dry
Mode / 36°
Horizontal
Upper limit / 0°
10°
30°
45°
Lower limit
for Heating Mode / 61°
CS-A73KE