CS-A73KE
Operation Details
2) Soft Dry Mode Operation
• The unit starts cooling operation until the room temperature reaches the setting temperature set on the Remote
Control, and then Soft Dry operation will start.
• During Soft Dry operation, the Indoor Fan will operate and stop at 4-second intervals at low speed.
• The operation will be switched on and off for up to 10 minutes "ON" and 6 minutes "OFF". Once Soft Dry opera-
tion is turned off, it stops for 6 minutes.
Time Delay Safety Control
• Once the compressor stops, it will not start for 3 minutes during Cooling operation.
Starting Current Control
• Same as Starting Current Control for Cooling Mode operation.
Anti-Freezing Control
• Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes waiting is valid during
compressor stops.)
Compressor Reverse Rotation
Protection Control
• Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For Soft Dry region, 6
minutes waiting is valid during compressor stops.)
Compressor Protection Control
• Same as Compressor Protection Control for Cooling Mode Operation.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during Soft Dry Operation.
• Fan speed rotates at SLo and Lo speed.
• Deodorizing Control.
* SLo: Indoor Fan rotates at 4-second intervals at low speed.
SLo
stop
Indoor
Fan
40"
ON
COMP
Lo
stop
stop
6'
40"
OFF
– 19 –
SLo
ON