CS-A73KE
Operation Details
Compressor Protection Control
• After the compressor starts for 50 seconds but the outdoor fan motor is still OFF, the compressor will stop and
restart automatically. (Time Delay Safety Control is valid).
Comp. operates for 50 secs.
and
Fan Motor OFF
• If the above phenomenon is repeated for 3 times, the compressor will stops.
• The above phenomenon is reset when there is a change to heating mode or stopped by Remote Control Switch.
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during cooling operation.
• Fan speed rotates in the range of Hi to Me.
• Deodorizing Control.
Indoor
Fan
Comp.
* 1 Fan Speed is Hi until the compressor stops (when the room temperature reaches
setting temperature).
* 2 Fan Speed is Me after the compressor restarts.
* SLo: Indoor Fan rotates at 4 second intervals at low speed.
Compressor
. .
. .
1
SLo
SLo
stop
stop
40"
30"
20"
ON
OFF
SLo
SLo
stop
stop
160"
40"
30"
OFF
ON
– 17 –
Compressor
restarts
(3 minutes waiting)
. .
. .