Panasonic CS-A73KE Service Manual page 23

Table of Contents

Advertisement

Operation Details
Automatic Fan Speed Mode
When Automatic Fan Speed is selected at Remote Control during heating operation.
• Fan speed rotates in the range of Me
• If use Manual Fan Speed,
Heating Operating Time Diagram
a b c d
°
39
C
Indoor
°
Heat
34
C
Exchanger
°
Temp.
30
C
°
28
C
OFF
Intake
Temp.
ON
Basic time
Compressor
4-way valve
Indoor Fan
Outdoor Fan
Operation LED
<Description of operation>
a – b : Hot start (Indoor fan = OFF)
b – d : Hot start (Indoor fan = SLo)
g – I : Indoor fan control (controlled during thermostat OFF)
g – h : Outdoor fan control (30 sec. Forced Operation) after compressor stops.
SLo according to the heat exchanger temperature.
( C)
45
39
34
30
Heat
Exchanger
Temperature
at above diagram will operate with setting Fan Speed.
e
f
g
30"
Lo -
Lo -
SLo SLo
Me
( C)
38
Lo
30
Lo-
28
SLo
15
OFF
h
i
j
k
l
m
3'
1' 40"
Lo -
Lo -
SLo SLo
– 22 –
CS-A73KE
n
o
p
q
r
s
Lo -
: Blinking
Operation
Stop

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-a93keCu-a73keCu-a123keCu-a93keCs-a123ke

Table of Contents