Temperature Measurement Value Correction Table; Power Ic Vref Feed Control Output - Sharp MD-MS701H Service Manual

Portable minidisc player/recorder
Hide thumbs Also See for MD-MS701H:
Table of Contents

Advertisement

MD-MS701H/MS702H

[2] Temperature measurement value correction table

Ambient temperature
o
o
+14
C ~ +16
+17
o
C ~ +19
o
+20
o
C ~ +22
o
o
o
+23
C ~ +25
o
o
+26
C ~ +27
o
o
+28
C ~ +30
*Meaning of values
Temperature reference = Value to be predicted to be measured by the microcomputer at reference temperature
o
(+23.6
C)
Temperature correction = Value to convert to measurement value at reference temperature (+23.6¯C)
*Determining the temperature correction value
Temperature detection characteristics formula
Ambient temperature (
Hence, TEMP input AD value = (463 - Ambient temperature)/2.876
The reference temperature (+23.6
by '1', temperature is determined.
For temperature correction, the input AD value is +/- inverted.

[3] Power IC VREF feed control output

Test/R-ROM write power input
Ambient temperature
o
o
-5
C ~ +9
C
o
o
+6
C ~ +21
C
o
o
+17
C ~ +32
C
o
o
+29
C ~ +44
C
Temperature correction
C
- 03h
C
- 02h
C
- 01h
± 00h
C
C
+ 01h
C
+ 02h
o
C) = (-2.876 x TEMP input AD value) + 463
o
C) is taken as a reference. (it is taken as '0'). Whenever the input AD value changes
Temperature correction
08h
07h
06h
05h
Center temperature
o
+ 15.0
C
+ 17.8
o
C
+ 20.7
o
C
o
+ 23.6
C
o
+ 26.5
C
o
+ 29.4
C
Center temperature
o
+ 0.5
C
o
+ 12.5
C
o
+ 23.6
C
o
+ 35.0
C
– 14 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Md-ms702h

Table of Contents