Adjustment; Test Disc; Extension Cable; Entering The Test Mode - Sharp MD-MS701H Service Manual

Portable minidisc player/recorder
Hide thumbs Also See for MD-MS701H:
Table of Contents

Advertisement

MD-MS701H/MS702H

Test disc

MD adjustment needs two types of disc, namely recording disc (low reflection disc) and playback-only disc (high
reflection disc).
Type
1
High reflection disc MMD-110 (TEAC Test MD)
2
Lowreflection disc
3
Low reflection disc
Note: Use the low reflection disc on which music has been recorded.
Extension Cable (See Fig.10)
1
Flat Cable for servicing 16Pin
2
Extension Connector for Service 16Pin

Entering the TEST mode

1. Setting at port (in standby state, disc-free state or power nonconnected state)
(1) Set the port as follows.
TEST1 : "Low"
TEST0 : "High"
(2) Press the PLAY button in the standby state (it is allowed to insert the disc or to connect the power supply).
(3) Test Mode STOP [ _ T E S T _ ]
2. Setting by special button operation (in standby state)
(1) Holding down the DISP button and ENTER button, press the PLAY button.
(2) Normal mode setting initialization (BASS setting, VOL setting, etc.)
(3) Indication of microcomputer version for one second [
(4) Whole LCD lighting for 2 seconds
(5) Test Mode STOP [ _ T E S T _ ]
*When the PLAY button is pressed during indication (3) and (4), the process proceeds to (5).
Leaving the TEST mode
(1) Press the STOP button in the TEST mode stop state or version indicating state or whole LCD lighting state.
(2) EEPROM rewrite-enable area updating, adjustment error setting (so as to adjust all the items when the power supply is turned
on in the normal mode)
(3) Change to standby state
Test Mode
1. AUTO 1 Mode
• Perform preliminary automatic adjustment.
• If the combination of mechanism and pickup
PWB has been changed, be sure to start from
AUTO1.
2. AUTO 2 Mode
• Perform ATT (attenuator) automatic adjustment.
• Perform continuous playback (error rate display,
jump test)
3. MANUAL 1 Mode
• Temperature is displayed. (Updating in real time)
• Seeing the displayed adjustment value, perform
preliminary manual adjustment.
(Error rate indication, jump test)
4. MANUAL 2 Mode
• Temperature is displayed. (Updating in real time)
• Seeing the displayed adjustment value
perform manfully the preliminary adjustment.
(Error rate indication, jump test)
• Continuous playback is performed
(error rate display, jump test).
5. RESULT 1 Mode
• The value adjusted in AUTO1 or MANUAL1 is
indicated.
• (Execution in servo "OFF" state").
6. RESULT 2 Mode
• The value adjusted in AUTO 2 or MANUAL 2 is
indicated.
• Adjustment value is changed manually.
(error rate display, jump test).
7. TEST-PLAY Mode
• Continuous playback from the specified address
is performed.
• 1 line, 10 lines or 400 lines manual jump is
performed.
• C1 error rate display (pit section), ADIP error
rate display (groove section)
• The temperature correction is performed only
when servo start is performed, but the posture
correction is not performed during continuous
playback.
Test disc
MMD-212 (TEAC Test MD)
Recording minidisc
Type
Microcomputer version

ADJUSTMENT

Parts No.
88GMMD-110
88GMMD-212
UDSKM0001AFZZ
Parts No.
QCNWK0110AFZZ
RUNTK0460AFZZ
PWB side
]
Destination
EEPROM version
8. TEST-REC Mode
9. NORMAL Mode
10. DIGITAL INPUT mode
11. ERROR INFORMATION
Mode
12. E
2
-PROM Mode
13. INNER Mode
– 10 –
Price Code
16 pin
QCNWK0110AFZZ
16pin Flat Cable
RUNTK0460AFZZ
Extension PWB for servicing 16pin
Figure 10
• Continuous record from the specified address is
performed.
• Change of record laser output(servo gain is also
changed according to laser output).
• The temperature correction is performed only
when servo start is performed, but the posture
correction is not performed during continuous
recording.
• The mode is changed from the TEST mode to
the normal mode without adjustment.
• In the normal mode the internal operation mode,
memory capacity, etc. areindicated.
• In the normal mode both temperature correction
and posture correction are perfomed.
• Digital input information is displayed.
• Error information is displayed.
• Error information is initialized
• Factors of digital servo are changed manually.
(Each servo is turned on individually.)
• Cut-off frequency of BASS1, BASS2 and BASS3
is selected manually.
• Temperature detection terminal voltage is
measured, and the reference value is set.
• Defaults are selected and set.
• Setting of EEPROM protect area is updated.
(In case of protect releasing)
• Determine the position where the INNER switch
is turned on. (only high reflection disc).
• The temperature correction is performed only
when servo start is performed, but the posture
correction is not performed.
Mecha Flexible PWB