Hoshizaki KM-100A Service Manual page 16

Self-contained crescent cuber
Hide thumbs Also See for KM-100A:
Table of Contents

Advertisement

thermistor reads a certain temperature at the evaporator outlet.
Dip Switch Setting
No. 1
No. 2
OFF
OFF
ON
OFF
OFF
ON
ON
ON
c) Drain Timer (S1 dip switch 3 & 4)
Once every ten freeze cycles, the drain valve opens to drain the water tank for the
time determined by the drain timer. These switches also determine the time to delay
completion of a defrost cycle, i.e. the minimum defrost time.
Do not change this setting, or the unit will not operate properly or produce high quality
ice.
Dip Switch Setting
No. 3
No. 4
OFF
OFF
ON
OFF
OFF
ON
ON
ON
T1: Time to drain the water tank
T2: Harvest timer at drain
Drain cycle always occurs on the 2nd harvest after startup. Then, depending on the
drain frequency control setting (dip switch 5 & 6), drain cycle occurs every cycle, or
every 2nd, 5th, or 10th cycle.
d) Drain Frequency Control (S1 dip switch 5 & 6)
The water tank drains at the frequency set by the drain frequency control.
The drain frequency control is factory-adjusted to drain the water tank every 10 cycles,
and no adjustment is required. However, where water quality is bad and the icemaker
needs a drain more often, the drain frequency can be adjusted as shown in the table
below.
Dip Switch Setting
No. 5
No. 6
OFF
OFF
ON
OFF
OFF
ON
ON
ON
Time
(seconds)
60
90
120
180
Time (seconds)
T1
T2
10
120
10
180
20
120
20
180
Frequency
every cycle
every 2 cycles
every 5 cycles
every 10 cycles