Sign In
Upload
Manuals
Brands
Panasonic Manuals
Fire Alarms
EBL128
Panasonic EBL128 Manuals
Manuals and User Guides for Panasonic EBL128. We have
8
Panasonic EBL128 manuals available for free PDF download: Planning Instructions, Operating Instructions Manual, User Manual, Daily User's Manual, Specification Sheet, Quick Start Manual
Panasonic EBL128 Planning Instructions (179 pages)
Fire Alarm System
Brand:
Panasonic
| Category:
Smoke Alarm
| Size: 3.96 MB
Table of Contents
Table of Contents
3
1 Introduction
10
2 Definitions / Explanations
12
Pesn Ab
12
Alarm Point
12
Smoke Detector
12
Sensor
12
Analog Detector
12
Analog) Sensor Base (ASB)
12
Conventional Detector
12
Conventional Detector Base (CDB)
12
Addressable
12
Old Detector
13
Conventional Zone Line
13
Addressable Zone Interface
13
Output Unit
13
Output / Control Output
13
Short Circuit Isolator
13
Display Unit (D.U.)
13
COM Loop
13
Control Unit (C.U.) / C.I.E
13
Fire Brigade Panel (FBP)
13
Control Panel (CP)
14
Led
14
External Indicator (LED)
14
Display / LCD
14
Door Open / Key Switch
14
Site Specific Data (SSD)
14
Software (S/W) / Firmware / System Program
14
Eblwin
14
Web-Server
14
3 Overview
15
The EBL128 C.I.e
15
Expansion Boards
15
Power Supply
15
S/W Versions
15
Documents
15
Applications
16
Pc S/W
16
4 Control & Indicating Equipment
17
COM Loop
19
A Single Break (Cut-Off) on the COM Loop
20
Several Breaks (Cut-Offs) on the COM Loop
21
Short-Circuit on the COM Loop
22
Programmable Voltage Outputs (S0-S1)
22
Programmable Relay Output (R0)
23
Relay Output for Routing Equipment (Fault Tx) (R1)
23
Programmable Input (I0)
23
DC Power Supply Outputs
24
RS232 Interfaces
24
RS485 Transceiver (Option)
24
Power Supply
24
Internal Power Supply
25
5 Expansion Boards 458X
26
Expansion Board Address Setting
27
Zones Expansion Board 4580
27
Type of Zone Line Input
28
Input States
28
Relays Expansion Board 4581
29
Inputs and Outputs Expansion Board 4583
29
I/O Matrix Board 4582
31
Generic
32
Fan Control
32
Zone Control
33
6 Peripheral Devices
34
COM Loop Units
34
Input Units
36
Addressable I/O Units
46
Alarm Devices (Addressable)
48
Short Circuit Isolators (Addressable)
50
Units for Hazardous (Ex) Areas
52
Other COM Loop Units
54
Units Connected to the RS485 Interface
55
External Fire Brigade Panels
55
Alert Annunciation Units
56
External Presentation Units
58
German Fire Brigade Panels
58
Units Connected to the RS232 Interface J5
59
Web-Servers
59
Units Connected to the RS232 Interface J3
60
Other Units
61
Alert Annunciation Controllers
61
External Leds
61
Alarm Devices (Sounders, Etc.)
62
Door Release Magnets
62
Boxes
62
7 Programmable Inputs
63
Control Unit Input I0 & Inputs and Outputs Exp. Board 4583, Input 0-4
64
Not Supervised
64
Supervised
64
3361 Unit Inputs In0 / Z & In1
65
8 Input Programming
66
Type (Trigger Conditions)
66
Logic
69
Not Supervised (Default)
69
Supervised
69
9 Programmable Outputs
70
Control Unit Outputs S0 - S1
71
Control Unit Output R0
72
Inputs and Outputs Expansion Board 4583 Output 0 - 1
72
The 3361 Unit Outputs Re0 - Re1
72
The 3364 Unit Outputs VO0, VO1 & VO2
73
The 3377 / 4477 Unit Output (Siren)
73
The 3378 Unit Output (Sounder)
73
The 3379 Unit Output (Sounder)
73
The 4380 Unit Output (Beacon)
73
The 4383 Unit Output (Light Indicator)
73
10 Output Programming
74
Type
74
Logic
75
Supervised
75
Output Signal Period
75
Control Expression
78
Trigger Conditions
78
Logical Operators
84
Control Expression Examples
84
11 Interlocking Function
88
Interlocking Programming
88
Interlocking Output
88
Interlocking Input
88
Interlocking Combination
88
Interlocking Indications
90
Information of Interlocking Combinations (H9)
90
Display Interlocking Information (H9/C1)
90
Activate Interlocking Output (H9/C2)
90
Reset Interlocking Output (H9/C3)
91
Disable Interlocking Output (H9/C4)
91
Re-Enable Interlocking Output (H9/C5)
91
Interlocking Control Expressions
91
12 Fire Door Closing Function
92
13 Functions / Services / Features
93
Sensor Value
93
Week Average Sensor Value
93
Decision Value
94
Alarm Algorithms for Smoke Detectors / Detection Levels / Offsets
94
Alarm Algorithm / Alternative Alarm Algorithm
95
Filtering Algorithm
96
Smouldering Smoke Algorithm
98
Performance Factor
99
Algorithms for Analog Heat Detectors
100
Class A1 Algorithm
100
Class A2 S Algorithm
101
Self Verification
101
Class B S Algorithm
101
Minimum / Maximum Sensor Values
102
2-Zone / 2-Address Dependence (Co-Incidence Alarm)
102
2-Zone Dependence
102
2-Address (-Unit) Dependence
103
Reset of 2-Zone / 2-Address Dependence
103
Alarm
103
Delayed Alarm
103
Alarm Verification Facility
104
Alert Annunciation
105
Alarm Acknowledgement Facility (AAF)
106
Quiet Alarm
109
Fire Alarm Type a and Fire Alarm Type B
109
Fire Alarm Type B
110
Fire Alarm Type a
110
Disable Zones, Alarm Points, Outputs, Etc
110
Disable Zone
111
Disable Zone-Address
111
Disable Output
111
Disable All Control, Ventilation, Exting or Interlocking Outputs
111
Disable / Re-Enable Alarm Devices
111
Disable / Re-Enable Outputs for Routing Equipment
111
Disable / Re-Enable Alert Annunciation Function
111
Disconnect / Re-Connect COM Loop
112
Disconnect / Re-Connect Zone Line Input
112
Disconnect / Re-Connect Addressable Zone Interface Input
112
Disable Interlocking Output
112
Test Mode
112
Test Alarm Devices
112
Test of Routing Equipment
113
Calibration of Supervised Outputs
113
Service Signal
113
Fault Signal (Fault Condition)
114
Alarm Texts
114
Creating the Alarm Texts Via Eblwin
114
Downloading Texts to the Dus 1728 / 1735 / 1736 and Ext. Fbps 1826 / 1828
116
Real Time Clock (RTC)
116
Daylight Saving Time
117
Time Channels 1-14
117
Time Channels 15-63
117
Event Log
118
Loss of Main Power Source
118
Fault: Loss of Main Power Source
118
LCD Backlight
118
Evacuate
118
14 Special New Zealand Functions
120
Alarm Devices
120
Silence Alarm Devices (Inside Switch)
120
New Zealand FB Silence Switch (Outside Switch)
120
Battery Faults
121
FAULT: Battery
121
FAULT: Low Battery Capacity
121
Watchdog Reset
122
Routing Equipment Isolate (Disable)
122
Acknowledged Alarm
122
15 Advanced Mode
123
Pulse up - down Counter
124
Pulse up - down Counter for Smoke
124
Pulse up - down Counter for Temperature
124
Fire Judgement
125
Pulse up - down Counter for Smoke & Temperature
125
Alarm Threshold Levels
125
Alarm Delay Time
126
Learning Function / Learning Period
127
Area Alarm Algorithms
127
Analog Data Output
128
Sensitivity Compensation
129
Self Diagnosis of Internal Devices
129
Address Setting Check
130
Polling LED
130
16 Control Unit Properties
131
Control Unit Properties Dialog Box
131
General Information
131
Configuration
131
Misc
131
Eblwin Control Unit Pop-Up Menu
132
Reset Alarm Counter
132
Software Version
132
Show Event Log
132
Restart
133
Delete
133
Properties
133
Add Web-Server
133
17 System Properties (Settings)
134
System Properties Dialog Box
134
Name
134
User Definable Text
134
System Properties, Page 2
136
18 Eblwin Menus
138
The File Menu
138
New
138
Open
138
Report
138
Save
138
Save as
138
Print Labels
138
Exit
139
The View Menu
139
Tree View
139
Deviations
139
Selected Loop
140
Alarm Points
140
Interlocking Combinations
140
External Faults
141
Technical Warnings
141
External Time Channels
141
The System Menu
142
Properties
142
Time Channels
142
Alarm Algorithms
144
Output Signal Periods
146
National Holidays
148
Two Zone Dependence
149
System Information
149
Edit Alarm Texts
149
User Data
150
The Tools Menu
150
The Help Menu
152
19 Download SSD
153
COM Loop Menu
153
Check Loop
153
Auto Generate Loop
154
SSD Download to the Control Unit
154
User Definable Text Messages Download
155
20 Download Software (S/W)
156
Software Download to the Control Unit
156
Advertisement
Panasonic EBL128 Planning Instructions (150 pages)
Fire Alarm System
Brand:
Panasonic
| Category:
Fire Alarms
| Size: 3.11 MB
Table of Contents
Table of Contents
3
1 Introduction
9
Revision
10
2 Definitions / Explanations
11
Alarm Point
11
Smoke Detector
11
Analog Detector
11
Sensor
11
Analog) Sensor Base (ASB)
11
Conventional Detector
11
Conventional Detector Base (CDB)
11
Addressable
11
Old Detector
12
Conventional Zone Line
12
Addressable Zone Interface
12
Output Unit
12
Output / Control Output
12
Short Circuit Isolator
12
Display Unit (D.U.)
12
COM Loop
12
Control Unit (C.U.) / C.I.E
12
Fire Brigade Panel (FBP)
12
Control Panel (CP)
13
Led
13
External Indicator (LED)
13
Display / LCD
13
Door Open / Key Switch
13
SSD / Site Specific Data
13
S/W / Software / System Program
13
3 Overview
14
The EBL128 C.I.e
14
S/W Versions
14
Documents
14
Applications
14
Pc S/W
14
4 Control & Indicating Equipment
15
COM Loop
17
A Single Break (Cut-Off) on the COM Loop
18
Several Breaks (Cut-Offs) on the COM Loop
19
Short-Circuit on the COM Loop
20
Programmable Voltage Outputs (S0-S1)
20
Programmable Relay Output (R0)
21
Relay Output for Routing Equipment (Fault Tx) (R1)
21
Programmable Input (I0)
21
DC Power Supply Outputs
22
RS232 Interfaces
22
RS485 Transceiver (Option)
22
Power Supply
22
Internal Power Supply
22
Internal Power Supply
23
5 Expansion Boards 458X
24
Expansion Board Address Setting
25
Zones Expansion Board 4580
25
Type of Zone Line Input
26
Input States
26
Relays Expansion Board 4581
27
Inputs and Outputs Expansion Board 4583
27
I/O Matrix Board 4582
29
Generic
30
Fan Control
30
Zone Control
31
6 Peripheral Devices
32
COM Loop Units
32
Input Units
33
Addressable I/O Units
40
Alarm Devices (Addressable Sounders)
42
Short Circuit Isolators (Addressable)
43
Units for Hazardous (Ex) Areas
45
Other COM Loop Units
45
COM Loop Addresses for Base Station and Wireless
47
Detectors
47
Units Connected to the RS485 Interface
48
External Fire Brigade Panels
48
Alert Annunciation Units
49
External Presentation Units
50
German Fire Brigade Panels
51
Units Connected to the RS232 Interface J5
52
Web-Servers
52
Units Connected to the RS232 Interface J3
53
Other Units
53
Alert Annunciation Controllers
53
External Leds
53
Alarm Devices (Sounders, Etc.)
54
Door Release Magnets
54
Boxes
54
7 Programmable Inputs
55
Control Unit Input I0 & Inputs and Outputs Exp. Board 4583, Input 0-4
56
Not Supervised
56
Supervised
56
3361 Unit Inputs In0 / Z & In1
57
8 Input Programming
58
Type (Trigger Conditions)
58
Logic
60
Not Supervised (Default)
61
Supervised
61
9 Programmable Outputs
62
Control Unit Outputs S0 - S1
63
Control Unit Output R0
64
Relay Outputs Expansion Board 4581 Output 0 - Output 7
64
Inputs and Outputs Expansion Board 4583 Output 0 - 1
64
The 3361 Unit Outputs Re0 - Re1
65
The 3364 Unit Outputs VO0, VO1 & VO2
65
The 3377 Unit Output (Siren)
65
The 3378 Unit Output (Sounder)
65
The 3379 Unit Output (Sounder)
65
10 Output Programming
66
Type
66
Logic
67
Supervised
67
Output Signal Period
67
Control Expression
70
Trigger Conditions
70
Logical Operators
73
Control Expression Examples
73
11 Interlocking Function
77
Interlocking Programming
77
Interlocking Output
77
Interlocking Input
77
Interlocking Combination
77
Interlocking Indications
79
Information of Interlocking Combinations (H9)
79
Display Interlocking Information (H9/C1)
79
Activate Interlocking Output (H9/C2)
80
Reset Interlocking Output (H9/C3)
80
Disable Interlocking Output (H9/C4)
80
Re-Enable Interlocking Output (H9/C5)
80
Interlocking Control Expressions
80
12 Fire Door Closing Function
81
13 Functions / Services / Features
82
Analog Smoke Detectors
82
Sensor Value
82
Week Average Sensor Value
82
Decision Value
83
Alarm Algorithms for Smoke Detectors / Detection Levels / Offsets
83
Alarm Algorithm / Alternative Alarm Algorithm
84
Filtering Algorithm
85
Smouldering Smoke Algorithm
87
Performance Factor
89
Analog Heat Detectors
89
Class A1 Algorithm
90
Class A2 S Algorithm
90
Class B S Algorithm
90
Self Verification
91
Minimum / Maximum Sensor Values
91
Two-Unit Dependence (Co-Incidence Alarm)
91
Two-Zone Dependence (Co-Incidence Alarm)
92
Delayed Alarm
92
Alarm Verification Facility
93
Alert Annunciation
93
Alarm Acknowledgement Facility (AAF)
95
Quiet Alarm
97
Fire Alarm Type a and Fire Alarm Type B
97
Fire Alarm Type B
98
Fire Alarm Type a
98
Disable Zones, Alarm Points, Outputs, Etc
98
Disable Zone
98
Disconnect / Re-Connect Zone Line
99
Disable Zone / Address
99
Disable Control Output
99
Disable / Re-Enable All Control, Exting. and Ventilation Outputs
99
Disable / Re-Enable Alarm Devices
99
Disable Outputs for Routing Equipment
99
Disable Interlocking Output
99
Disconnect / Re-Connect COM Loop
100
Test Mode
100
Test Alarm Devices
100
Test of Routing Equipment
100
Calibration of Supervised Outputs
101
Service Signal
101
Fault Signal (Fault Condition)
101
Alarm Texts
101
Creating the Alarm Texts Via Win128
102
Downloading Texts to the EPU 1728, Aaus 1735 / 1736 and Ext. Fbps 1826 / 1828
104
Real Time Clock (RTC)
104
Daylight Saving Time
104
Time Channels 1-4
105
Time Channels 5-12
105
Event Log
105
Loss of Main Power Source
105
Fault: Loss of Main Power Source
106
LCD Backlight
106
Win128 Tools Menu
106
14 Special New Zealand Functions
108
Alarm Devices
108
Silence Alarm Devices (Inside Switch)
108
New Zealand FB Silence Switch (Outside Switch)
108
Battery Faults
109
FAULT: Battery
109
FAULT: Low Battery Capacity
109
Watchdog Reset
110
Routing Equipment Isolate (Disable)
110
Acknowledged Alarm
110
15 Cyber Sensor Functions
111
Pulse up - down Counter
112
Pulse up - down Counter for Smoke
112
Pulse up - down Counter for Temperature
112
Fire Judgement
112
Pulse up - down Counter for Smoke & Temperature
112
Alarm Threshold Levels
113
Learning Function / Learning Conditions
113
Learning Conditions
113
Alarm Delay Time
115
Analog Data Output
116
Sensitivity Compensation
116
Self Diagnosis of Internal Devices
116
Address Setting Check
117
16 Control Unit Properties (Settings)
118
Control Unit Properties
118
AAF Times
118
Alert Annunciation Times
118
Time Channels
119
Control Unit Properties
119
Alarm Algorithms
121
Parameters for Smoke Algorithms
122
Parameters for Heat Algorithms
122
Parameters for Combined Decision Algorithm
123
National Holidays
123
Output Signal Periods
125
Advanced
126
Main Power Loss Fault
126
Alarm Reset
126
Door Closing by Time
126
Zone Line Input Alarm Delay Time
127
Miscellaneous
127
Statistics
128
17 Cable Types
129
COM Loop Cables
129
Ext. FBP / EPU / AAU Cables
129
Conventional Zone Line Cables
129
Alarm Device Cables
129
Other Equipment Cables
129
Panasonic EBL128 Operating Instructions Manual (152 pages)
Fire Alarm System
Brand:
Panasonic
| Category:
Security System
| Size: 1.96 MB
Table of Contents
Operating Instructions
1
Table of Contents
3
1 Introduction
9
2 Definitions / Explanations
11
Pesn Ab
11
Alarm Point
11
Smoke Detector
11
Sensor
11
Analog Detector
11
Analog) Sensor Base (ASB)
11
Conventional Detector
11
Conventional Detector Base (CDB)
11
Addressable
11
Old Detector
12
Conventional Zone Line
12
Addressable Zone Interface
12
Output Unit
12
Output / Control Output
12
Short Circuit Isolator
12
Display Unit (D.U.)
12
COM Loop
12
Control Unit (C.U.) / C.I.E
12
Fire Brigade Panel (FBP)
12
Control Panel (CP)
13
Led
13
External Indicator (LED)
13
Display / LCD
13
Door Open / Key Switch
13
Site Specific Data (SSD)
13
Software (S/W) / Firmware / System Program
13
Eblwin
13
Web-Server
13
3 Overview
14
The EBL128 C.I.e
14
S/W Versions
14
Documents
14
Applications
14
Pc S/W
14
4 Control & Indicating Equipment
16
5 LED Indicators and Push Buttons
18
6 Normal Operation
23
The Display in EBL128
23
LCD Backlight
23
The LCD Information Priority Order
23
7 User Level, User Name & Password
25
User Level 1
26
User Level 2A
26
User Level 2B
27
User Level 2C
28
User Level 3A
29
Access Level 3B
29
Access Level 4
29
8 Silence Alarm Devices
31
Silence Alarm Devices (Inside Switch)
32
New Zealand FB Silence Switch (Outside Switch)
32
9 Disable / Re-Enable Alarm Devices
34
10 "Silence Buzzer
35
Buzzer
35
11 Disable / Re-Enable All Control, Extinguishing, Ventilation and Interlocking Outputs
36
12 Evacuate, Alert Annunciation Acknowledge and Disable
37
Evacuate
37
Alert Annunciation Acknowledge
37
Disable
37
13 German Functions / Units
38
Push-Button "ÜE Prüfen
38
Button "Brandfall Steuerungen Ab
38
Indication "Brandfall Steuerungen Ab
39
Button "Akustische Signale Ab
39
Indication "Akustische Signale Ab
39
Indication in Button "Akustische Signale Ab
39
The Buzzer in the C.I.e
39
Button "ÜE Ab
39
Indication "ÜE Ab
40
Disablements of Outputs; Information in the C.I.e. and FAT Display Respectively
40
14 Door Open
41
LED "Door Open
41
Outputs for Routing Equipment (Fire Brigade Tx and Fault Tx)
41
Silence Buzzer
41
15 Technical Address / Presentation Number
42
Technical Address for COM Loop Units
42
Presentation Number
42
16 Alarm Types
43
Pre-Warning
43
Fire Alarm
44
Fire Alarm Menu (X1-X9)
47
Alert Annunciation Alarm (AA Alarm)
50
Co-Incidence Alarm (Two-Unit / -Zone Dependence)
51
Heavy Smoke Alarm / Heavy Heat Alarm
51
Key Cabinet Alarm
52
Key Cabinet Opened before a Fire Alarm
52
Key Cabinet Opened in Conjunction with a Fire Alarm
53
Quiet Alarm
53
Alarm Acknowledgement Facility (AAF)
53
17 Alarm Reset
55
Pre-Warning Reset
55
Fire Alarm Reset
55
All
55
Single
55
Single with Automatic Disablement
56
Co-Incidence Alarm
57
Heavy Smoke / Heat Alarm Reset
57
Key Cabinet Alarm Reset
57
Quiet Alarm Reset
57
Alarm Acknowledgement Facility (AAF) Reset
57
Acknowledged Alarm
58
Isolated Alarm
58
18 Fault
59
Fault Messages
60
Fault Acknowledge
72
19 Commissioning an EBL128
73
20 SSD Programming & Download
74
SSD Programming
74
Auto Generating SSD
74
SSD Download
74
Download of Alarm Texts
76
21 Software (S/W) Download
77
Download of S/W in EBL128 (C.I.e.)
77
Earlier S/W Version Download
78
S/W Download in Display Units
78
22 Restart
79
Boot Menu
81
23 Access
83
24 Perform Monthly Test (H1)
85
25 Disable or Re-Enable (H2)
87
Disable Zone (H2/B1)
88
Disable Zone / Address (H2/B2)
89
Disable Output (H2/B3)
90
Disable All Control, Ventilation, Exting or Interlocking Outputs (H2/B4)
92
Re-Enable Zone (H2/B5)
93
Re-Enable Zone / Address (H2/B6)
94
Re-Enable Output (H2/B7)
95
Re-Enable All Control, Ventil, Exting or Interlocking Outputs (H2/B8)
97
Disable / Re-Enable Alarm Devices (H2/B9)
98
Disable / Re-Enable Outputs for Routing Equipment (H2/B10)97
99
Disable / Re-Enable Alert Annunciation Function (H2/B11)
100
26 Set Calendar and Clock (H3)
101
Daylight Saving Time
102
27 Present System Status (H4)
103
Disablement (H4/U1)
103
Disablement by Time Channel (H4/U2)
104
Sensor Values (H4/U3)
105
Reset of a Week Average Sensor Value
108
Sensors Activating SERVICE Signal (H4/U4)
109
Technical Warning (H4/U5)
110
Event Log (H4/U6)
111
Version and Alarm Counter (H4/U7)
112
28 Service (H5)
113
Calibration of Supervised Outputs (H5/A1)
114
Sensitive Fault Detection Mode (H5/A2)
116
Service Mode for COM-Loop (H5/A3)
117
Display Current Consumption in Unit (H5/A4)
119
Display Current Consumption on COM-Loop (H5/A5)
120
Display Statistics for COM Loop (H5/A6)
121
Activate Address Setting Mode for du (H5/A7)
122
Show Information about Site Specific Data (H5/A8)
123
29 FAULT Acknowledge (H6)
125
30 Perform ZONE TEST (Test Mode) (H7)
126
31 Maintenance (H8)
128
Disconnect / Re-Connect COM Loop (H8/S1)
128
Disconnect / Re-Connect Zone Line Input (H5/A2)
129
Disconnect / Re-Connect Addressable Zone Interface Input
130
Acknowledge SERVICE Signal (H8/S4)
131
Restore Weekly Average to Default (H8/S5)
132
Test of Alarm Devices (H8/S6)
133
Safe Shut down of Control Unit (H8/S7)
134
Activate Zone-Address in Alarm Mode (H8/S8)
135
Activate Output (H8/S9)
137
Reset Activated Output (H8/S10)
139
Advertisement
Panasonic EBL128 Operating Instructions Manual (142 pages)
Fire Alarm System
Brand:
Panasonic
| Category:
Fire Alarms
| Size: 1.65 MB
Table of Contents
Operating Instructions
1
Table of Contents
3
MEW01091 Rev
5
1 Introduction
8
Revision
8
Alarm Point
10
Smoke Detector
10
Sensor
10
Analog Detector
10
Analog) Sensor Base (ASB)
10
Conventional Detector
10
Conventional Detector Base (CDB)
10
Addressable
10
Old Detector
11
Conventional Zone Line
11
Addressable Zone Interface
11
2 Definitions / Explanations
10
Pewf&Ste Ab
10
COM Loop
11
Control Unit (C.U.) / C.I.E
11
Display Unit
11
Fire Brigade Panel (FBP)
11
Output / Control Output
11
Output Unit
11
Short Circuit Isolator
11
Control Panel (CP)
12
Display / LCD
12
Door Open / Key Switch
12
External Indicator (LED)
12
Led
12
S/W / Software / System Program
12
SSD / Site Specific Data
12
Applications
13
Documents
13
3 Overview
13
Pc S/W
13
S/W Versions
13
The EBL128 C.I.e
13
4 Control & Indicating Equipment
14
5 LED Indicators and Push Buttons
16
6 Normal Operation
22
The Display in EBL128
22
LCD Backlight
22
The LCD Information Priority Order
22
7 Access Levels
24
EBL128 Operating Instructions V1.1
24
Access Level 1
25
Access Level 2A
25
Access Level 2B
26
Access Level 3A
27
Access Level 3B
27
Access Level 4
28
8 "Silence Alarm Devices
29
Silence Alarm Devices (Inside Switch)
29
New Zealand FB Silence Switch (Outside Switch)
30
9 Disable / Re-Enable Alarm Devices
31
10 "Silence Buzzer
32
Buzzer
32
11 Disable / Re-Enable All Control, Extinguishing and Ventilation Outputs
33
Alert Annunciation Acknowledge
34
Disable
34
Evacuate
34
12 Evacuate, LED Test, Alert Annunciation Acknowledge and Disable
34
LED Test
34
Button "Brandfall Steuerungen Ab
35
13 German Functions / Units
35
Push-Button "ÜE Prüfen
35
Button "Akustische Signale Ab
36
Button "ÜE Ab
36
Indication "Akustische Signale Ab
36
Indication in Button "Akustische Signale Ab
36
Indication "Brandfall Steuerungen Ab
36
The Buzzer in the C.I.e
36
Disablements of Outputs; Information in the C.I.e. and FAT Display Respectively
37
Indication "ÜE Ab
37
14 Door Open
38
LED "Door Open
38
Outputs for Routing Equipment (Fire Brigade Tx and Fault Tx)
38
Silence Buzzer
38
Presentation Number
39
15 Technical Address / Presentation Number
39
Technical Address for COM Loop Units
39
16 Alarm Types
40
Pre-Warning
40
Fire Alarm
41
Fire Alarm Menu (X1-X9)
44
Alert Annunciation Alarm (AA Alarm)
47
Co-Incidence Alarm (Two-Unit / -Zone Dependence)
48
Heavy Smoke Alarm / Heavy Heat Alarm
48
Key Cabinet Alarm
49
Key Cabinet Opened before a Fire Alarm
49
Key Cabinet Opened in Conjunction with a Fire Alarm
50
Key Cabinet Alarm, Danish (DBI) Convention
50
Quiet Alarm
50
Alarm Acknowledgement Facility (AAF)
51
17 Alarm Reset
52
Fire Alarm Reset
52
Multiple Reset
52
Single Encapsulated Reset
52
Alert Annunciation
53
Co-Incidence Alarm
53
Pre-Warning Reset
52
Alarm Acknowledgement Facility (AAF) Reset
54
Heavy Smoke / Heat Alarm Reset
54
Key Cabinet Alarm Reset
54
Quiet Alarm Reset
54
Acknowledged Alarm
55
Isolated Alarm
55
18 Fault
56
Fault Messages
57
Fault Acknowledge
69
19 Commissioning an EBL128
70
Auto Generating SSD
71
SSD Download
71
SSD Programming
71
20 SSD Programming & Download
71
Download of Alarm Texts
72
Download of S/W in EBL128 (C.I.e.)
73
21 Software (S/W) Download
73
(C.I.e.)
74
Upgrade of S/W Version 1.0.X to Version 1.1.X in EBL128
74
Earlier S/W Version Download
75
S/W Download in Display Units
75
22 Restart
76
Boot Menu
78
23 Access
80
24 Perform Monthly Test (H1)
81
25 Disable or Re-Enable (H2)
83
Disable Zone (H2/B1)
83
Disable Zone / Address (H2/B2)
85
Disable Output (H2/B3)
86
Disable All Control, Extinguishing, Ventilation and Alarm Device Outputs (H2/B4)
87
Re-Enable Zone (H2/B5)
88
Re-Enable Zone / Address (H2/B6)
89
Re-Enable Output (H2/B7)
90
Re-Enable All Control, Extinguishing, Ventilation or Alarm Device Outputs (H2/B8)
92
Disable or Re-Enable Outputs for Routing Equipment (H2/B9)
93
De-Activate Alert Annunciation Function (H2/B10)
94
26 Set Calendar and Clock (H3)
95
Daylight Saving Time
96
Disablement (H4/U1)
97
27 Present System Status on Display (H4)
97
Disablement by Time Channel (H4/U2)
98
Sensor Values (H4/U3)
99
Reset of a Week Average Sensor Value
101
Sensors Activating SERVICE Signal (H4/U4)
102
Event Log (H4/U5)
103
Show Configuration and Alarm Counter (H4/U6)
104
28 Service (H5)
105
Access Code for Service and Maintenance
106
Disconnect / Re-Connect COM Loop (H5/A1)
107
Disconnect / Re-Connect Zone Line Input (H5/A2)
108
Calibration of Supervised Outputs (H5/A3)
109
Sensitive Fault Detection Mode (H5/A4)
110
Service Mode for COM-Loop (H5/A5)
111
Show Information about Site Specific Data (H5/A6)
113
Display Current Consumption on COM Loop (H5/A7)
114
Display Statistics for COM Loop (H5/A8)
115
Activate Address Setting Mode for du (H5/A9)
116
29 Acknowledge FAULTS (H6)
117
30 Perform ZONE TEST (Test Mode) (H7)
118
Access Code for Service and Maintenance
120
31 Maintenance (H8)
120
Acknowledge SERVICE Signal (H8/S1)
121
Restore Weekly Average to Default (H8/S2)
122
Test of Alarm Devices (H8/S3)
123
Safe Shut down of Control Unit (H8/S4)
124
Activate Address in Alarm Mode (H8/S5)
125
Change Access Code for Service and Maintenance (H8/S6)
127
Change Access Code for PC-Communication (H8/S7)
128
Activated Interlocking Outputs/Inputs (H9/C1)
129
Panasonic EBL128 User Manual (42 pages)
Fire alarm system
Brand:
Panasonic
| Category:
Fire Alarms
| Size: 0.72 MB
Table of Contents
Table of Contents
3
1 Introduction
5
2 Front
6
3 Log on to the Control Unit (C.I.e.)
7
4 Perform Monthly Test (H1)
11
5 Disable or Re-Enable (H2)
12
Disable Zone (B1)
12
Disable Zone-Address (B2)
13
Disable Output (B3)
14
Disable All Control, Ventilation, Exting or Interlocking Outputs
15
(B4)
15
Re-Enable Zone (B5)
16
Re-Enable Zone-Address (B6)
17
Re-Enable Output (B7)
18
Re-Enable All Control, Ventilation, Exting or Interlocking Outputs (B8)
19
Disable / Re-Enable Alarm Devices (B9)
20
Disable / Re-Enable Outputs for Routing Equipment (B10)
21
Disable / Re-Enable Alert Annunciation Function (B11)
22
6 Set Calendar and Clock (H3)
23
7 Present System Status (H4)
24
Disablement (U1)
24
Disablement by Time Channel (U2)
25
Sensor Values (U3)
26
Sensors Activating SERVICE Signal (U4)
27
Technical Warning (U5)
28
Event Log (U6)
29
Version and Alarm Counter (U7)
30
8 FAULT Acknowledge (H6)
31
9 Perform ZONE TEST (H7)
32
10 Interlocking Outputs and Inputs (H9)
33
Activated Interlocking Outputs / Inputs (C1)
33
Activate Interlocking Output (C2)
34
Reset Interlocking Output (C3)
35
Disable Interlocking Output (C4)
36
Re-Enable Interlocking Output (C5)
37
11 Change Password (H10)
38
12 Revision History
39
Panasonic EBL128 Daily User's Manual (18 pages)
Brand:
Panasonic
| Category:
Smoke Alarm
| Size: 0.6 MB
Table of Contents
Table of Contents
3
1 Introduction
4
2 Description of the Front
5
Led Indicators
6
Push Buttons
7
Display
7
3 Access Levels
8
4 Log on to the Control Unit (C.I.e.)
8
How to Log on
8
5 Navigation / General Procedures
9
6 Perform Monthly Test (H1)
10
7 Disable or Re-Enable (H2)
11
Sub Menu List (B1 - B11)
11
8 Set Calender and Clock (H3)
13
9 Present System Status (H4)
14
Sub Menu List (U1 - U8)
14
10 Fault Acknowledge (H6)
15
11 Perform Zone Test (H7)
16
12 Interlocking Outputs and Inputs (H9)
17
Sub Menu List (C1 - C5)
17
13 Change Password (H10)
17
Panasonic EBL128 Specification Sheet (2 pages)
Fire alarm system
Brand:
Panasonic
| Category:
Fire Alarms
| Size: 0.1 MB
Panasonic EBL128 Quick Start Manual (2 pages)
Brand:
Panasonic
| Category:
Smoke Alarm
| Size: 0.13 MB
Advertisement
Related Products
Panasonic EBL512
Panasonic EBL512 G3 V1.1.x
Panasonic EBL512 G3 5000
Panasonic EBGD55 - MINI CELLPHONE
Panasonic EB-GD76
Panasonic EB-GD96
Panasonic EB-SA7
Panasonic EB-GD87
Panasonic EB-HF20/E
Panasonic EB-CD400A
Panasonic Categories
Camcorder
Air Conditioner
TV
Digital Camera
Cordless Telephone
More Panasonic Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL